Greenlee TM-500iTest telephone 52062073 Datenbogen

Produktcode
52062073
Seite von 10
MONITOR / TALK Switch
Polarity LED
MUTE Button
Volume Control Switch
Operation
Talk Mode
Slide switch to 
TALK to go off-hook (connect).
This device is for connection to TNV3 network voltages 
only. Use this unit only on standard analog Telecom 
networks. If this unit is 
accidentally connected to an 
over-voltage condition, it will attempt to protect itself:
• Raw battery and V up to 90 VDC:  Clicks and/or beeps 
heard repeatedly in the earpiece while fault exists.
• 90 V to 180 V:  Continuous ringing heard.
Disconnect the unit as soon as possible as damage 
may occur.
Connection to voltages in excess of 200 VDC can cause 
permanent damage to the unit.
Slide switch to 
MONITOR to go back on-hook (disconnect).
The TM-500 test set is DSL compatible and can be used 
on a DSL enabled line without the need of an external DSL 
filter.
Monitor Mode (high impedance)
Slide switch to 
MONITOR.
In this mode, the unit can monitor audio signals on the line. 
No power from the line is needed.
 
Mute
Press and hold the 
MUTE button to cut off transmission 
during a call.
Volume Control (Talk mode only)
Slide switch to 
12, or 3 to satisfy earpiece volume level 
requirements in Talk mode.
Polarity Test
Press 
Pol and observe the polarity LED. In the presence of 
power, the LED will light either red or green:
• Red LED:  red lead is connected to Tip/A/+Ve.
• Green LED:  red lead is connected to Ring/B/–Ve.
During ringing, both red and green LEDs will light in turn 
and may appear amber.
Identification
Last Number Redial and Pause
Press 
LNR/Pause immediately after off-hook to redial the 
previous number dialed. In Store mode, press 
LNR/Pause 
to insert a 4 second pause in a memory. Press 
LNR/Pause 
again to increase the pause duration.
Flash
Press 
Flash to generate a timed line break. The settings 
are 100 ms (default), 300 ms, or 600 ms.
Storing a Number in Memory
There are 10 memory locations, one under each of the 
dialing digits (0–9).
While connected to a line and in Talk mode:
1. Press 
STO to enter Store mode.
2.  Enter the telephone number to be stored.
3. Press 
STO and a location (0–9) to store. The number is 
stored under the button chosen.
In memory you may also store 
*
#Flash, or LNR/Pause
These will be redialed as they were entered.
Memory Recall—Dialing a Number  
from a Memory Location
While connected to a line and in Talk mode:
1. Press 
RCL.
2.  Press the location digit (0–9). The stored number under 
that button will be redialed.
Multiple memories can be recalled, one after the other.
Pulse Dialing
In Talk mode, press 
Pulse before dialing. Pulse mode is 
confirmed by a single high beep in the earpiece. Dialing 
mode will automatically revert to Tone when the line is 
disconnected or the unit is switched to Monitor mode.
Mixed Pulse and Tone Dialing
Select Pulse mode as above and dial the pulse digits.  
Press 
*
 
(Tone) and then dial the tone digits (the star will 
not be dialed out). This will be stored in the Last Number 
Redial memory as dialed. Redialing will be mixed mode if 
in Pulse mode when redial is attempted. If Tone mode is 
selected, all digits will be dialed in Tone including the star.
Setup Mode
In Talk mode, press 
STO and 
*
 together. Use the following 
table and the numerical keys to set up the unit to meet 
your local requirements.
ETSI
USA
Pulse Rate
10 pps
@
$
20 pps
Flash Duration
100 ms
@
300 ms
600 ms
$
DTMF Level
High
$
Low
@
Make/Break Ratio
60/40
@
$
67/33
Send Level
High
$
Low
@
Sidetone
High
$
Low
@
Defaults
ETSI
@
USA
$
Press 
*
 to save changes and exit, or slide switch to 
MONITOR to ignore changes.
Ground-Start Lines
Using an adapter to connect a green wire to Pin 5 of the 
line cord jack:
1.  Connect green wire to ground.
2.  In Talk mode, press 
G/S momentarily.
3.  Check for a dial tone.
Earth Loop Recall
Using an adapter to connect a green wire to Pin 5 of the 
line cord jack:
1.  In Talk mode on a looped line and with the green wire 
to ground, press 
ERL momentarily.
2.  Check for a second dial tone.
Hands-Free Mode
The TM-500 can be used hands-free with the headset 
plugged into its socket at the base of the unit. Only use the 
supplied headset.
Headset
Jack
3–Red
5–Green
Earth Connection
4–Black