4d Systems uCAM-II-76LENS Datenbogen

Seite von 25
4D SYSTEMS                                                                                                  µCAM-II 
 
 
 © 2014 4D SYSTEMS                       Page 8 of 25                   www.4dsystems.com.au 
 
µC
AM
 –
 II
 Se
rial
 Ca
mer
a M
od
ul
 
Figure 3.2: SYNC Command Timing Diagram 
 
Please  refer  to  section  7.1  for  more  information 
regarding synchronising the uCAM-II. 
 
5.3. Auto-Baud Detect 
 
The  module  can  auto-detect  the  baud  rate  of  the 
incoming  command.  The  host  should  make 
connection with one of the following baud rates: 
 
• 
9600 bps 
• 
14400 bps 
• 
56000 bps 
• 
57600 bps 
• 
115200 bps 
• 
921600 bps 
 
The  module  will  keep  using  the  last  baud  rate 
either  autobauded  or  manually  set  until  the  next 
power cycle, or “full reset”. 
 
Note:    The  baud  rate  can  be  set  higher  than  the 
baud  rated  determined  by  the  Auto-Baud  detect 
function. Refer to Section 5.4 
 
5.4. Setting the Baud Rates 
 
You  can  set  Baud  rates  using  the  Set  Baud 
command, refer to the table in section 6.5 
 
Note:  Baud  rate  changes  holds  until  “full  reset” 
command  is  sent  or  Power  cycle  occurs.  So,  you 
can  synchronise  at  any  of  the  Auto-detect  Baud 
rate. 
 
5.5. Sleep mode 
 
After  the  camera  has  been  idle  for  15  seconds  it 
enters  sleep  (low  power)  mode.  To  wake  up  the 
camera  in  this  state  it  is  necessary  to  send  the 
‘Sync’ command. If the  camera  is required to stay 
awake,  it  is  recommended  to  periodically  end  a 
‘Sync’  command,  such  as  every  10  seconds,  to 
prevent  the  camera  going  to  sleep  if  no  other 
commands  are  being  sent.  If  communications  are 
occurring  between  the  Host  and  the  camera,  the 
camera will not go to sleep until it has been idle for 
15 seconds.