Atmel Evaluation Kit AT91SAM9X25-EK AT91SAM9X25-EK Datenbogen
Produktcode
AT91SAM9X25-EK
66
SAM9X25 [DATASHEET]
11054E–ATARM–10-Mar-2014
The device also handles some class requests defined in the CDC class.
Unhandled requests are STALLed.
11.5.3.4 Communication Endpoints
There are two communication endpoints and endpoint 0 is used for the enumeration process. Endpoint 1 is a 64-byte
Bulk OUT endpoint and endpoint 2 is a 64-byte Bulk IN endpoint. SAM-BA Boot commands are sent by the host through
endpoint 1. If required, the message is split by the host into several data payloads by the host driver.
Bulk OUT endpoint and endpoint 2 is a 64-byte Bulk IN endpoint. SAM-BA Boot commands are sent by the host through
endpoint 1. If required, the message is split by the host into several data payloads by the host driver.
If the command requires a response, the host can send IN transactions to pick up the response.
Table 11-6. Handled Class Requests
Request
Definition
SET_LINE_CODING
Configures DTE rate, stop bits, parity and number of
character bits.
character bits.
GET_LINE_CODING
Requests current DTE rate, stop bits, parity and number
of character bits.
of character bits.
SET_CONTROL_LINE_STATE
RS-232 signal used to tell the DCE device the DTE
device is now present.
device is now present.