Atmel Evaluation Kit AT91SAM9M10-G45-EK AT91SAM9M10-G45-EK Datenbogen
Produktcode
AT91SAM9M10-G45-EK
281
SAM9M10 [DATASHEET]
6355F–ATARM–12-Mar-13
23.4.4
ECC Status Register 2
Name:
ECC_SR2
Access:
Read-only
• RECERR8: Recoverable Error in the page between the 2048th and the 2303rd bytes
Fixed to 0 if
TYPECORREC = 0.
0 = No Errors Detected.
1 = Errors Detected. If MUL_ERROR is 0, a single correctable error was detected. Otherwise multiple uncorrected errors
were detected
were detected
• ECCERR8: ECC Error in the page between the 2048th and the 2303rd bytes
Fixed to 0 if
TYPECORREC = 0.
0 = No Errors Detected.
1 = A single bit error occurred in the ECC bytes.
Read ECC Parity 8 register, the error occurred at the location which contains a 1 in the least significant 24 bits.
• MULERR8: Multiple Error in the page between the 2048th and the 2303rd bytes
Fixed to 0 if
TYPECORREC = 0.
0 = No Multiple Errors Detected.
1 = Multiple Errors Detected.
• RECERR9: Recoverable Error in the page between the 2304th and the 2559th bytes
Fixed to 0 if
TYPECORREC = 0.
0 = No Errors Detected.
1 = Errors Detected. If MUL_ERROR is 0, a single correctable error was detected. Otherwise multiple uncorrected errors
were detected.
were detected.
• ECCERR9: ECC Error in the page between the 2304th and the 2559th bytes
Fixed to 0 if
TYPECORREC = 0.
0 = No Errors Detected.
1 = A single bit error occurred in the ECC bytes.
Read ECC Parity 9 register, the error occurred at the location which contains a 1 in the least significant 24 bits.
• MULERR9: Multiple Error in the page between the 2304th and the 2559th bytes
Fixed to 0 if
TYPECORREC = 0.
0 = No Multiple Errors Detected.
31
30
29
28
27
26
25
24
–
MULERR15
ECCERR15
RECERR15
–
MULERR14
ECCERR14
RECERR14
23
22
21
20
19
18
17
16
–
MULERR13
ECCERR13
RECERR13
–
MULERR12
ECCERR12
RECERR12
15
14
13
12
11
10
9
8
–
MULERR11
ECCERR11
RECERR11
–
MULERR10
ECCERR10
RECERR10
7
6
5
4
3
2
1
0
–
MULERR9
ECCERR9
RECERR9
–
MULERR8
ECCERR8
RECERR8