DC voltage 
: 0 to 1V DC    Input impedance (1M  or more) 
 
Allowable input voltage (5V or less) 
 
Allowable signal source resistance (2k  or less)  
         
: 0 to 5V DC, 1 to 5V DC, 0 to 10V DC    Input impedance (100k  or more) 
 
Allowable input voltage (15V or less) 
 
Allowable signal source resistance (100  or less)  
Control output (OUT1) 
          
Relay contact  : 1a, Control capacity   3A  250V AC (resistive load) 
                              
1A  250V AC (inductive load cosø=0.4) 
 
Electrical life, 100,000 cycles 
 
Non-contact voltage (For SSR drive): 12
+2
  0
V DC maximum 40mA (short circuit protected) 
 
DC current       : 4 to 20mA DC, Load resistance, maximum 550  
A1 output 
                 
Action                : ON/OFF action 
    
Hysteresis 
: 0.1 to 100.0  ( ), or 1 to 1000 
                 
Output               : Relay contact, 1a 
                             Control capacity, 3A  250V AC (resistive load) 
 
Electrical life, 100,000 cycles 
Control action 
      PID action (with auto-tuning function) 
 
PI action: When derivative time is set to 0 
 
PD action (with auto-reset function): When integral time is set to 0 
     
P action (with auto-reset function): When both derivative and integral times are set to 0. 
          ON/OFF action: When proportional band is set to 0 or 0.0 
        OUT1 proportional band : 0 to 1000  (2000 ), 0.0 to 999.9   ( ) or 0.0 to 100.0% 
 
(ON/OFF action when set to 0 or 0.0) 
        Integral time    
 : 0 to 1000sec (OFF when set to 0) 
        Derivative time    
 : 0 to 300sec (OFF when set to 0) 
              OUT1 proportional cycle : 1 to 120sec (Not available for DC current output type) 
 
ARW 
 : 0 to 100% 
  OUT1 output hysteresis  : 0.1 to 100.0  ( ), or 1 to 1000 
  OUT1 output limit 
: 0 to 100% (DC current output type: –5 to 105%) 
Circuit insulation configuration 
 
 
 
 
 
Insulation resistance  : 10M   or more, at 500V DC 
Dielectric strength   
: 1.5kV AC for 1 minute between input terminal and power terminal 
 
1.5kV AC for 1 minute between output terminal and power terminal 
 
Supply voltage 
: 100 to 240V AC  50/60Hz,  24V AC/DC  50/60Hz 
 
Allowable voltage fluctuation: 100 to 240V AC: 85 to 264V AC,      24V AC/DC: 20 to 28V AC/DC 
Power consumption  : Approx. 8VA 
Ambient temperature
 
: 0 to 50  (32 to 122 ) 
Ambient humidity    
: 35 to 85%RH (no condensation) 
Weight  
: Approx. 200g 
External dimension 
: 48 x 48 x 96.5mm (W x H x D) 
Material  
: Flame-resistant resin (Case) 
Color 
: Ash gray (Case) 
Attached function 
:
 [Set value lock], [Sensor correction], [Auto/manual control switching], 
  [Input abnormality indication] 
 
Output status 
OUT1 OUT2 
Output status 
selection when 
input abnormal
 
Contents and 
Indication 
Direct action 
Reverse action
Direct action 
Reverse action 
 
ON (20mA) or 
OUT1 high   
limit value 
ON or 
OUT2 high limit 
value 
 
Overscale 
Measured value 
has exceeded 
Indication range 
high limit value. 
"
" flashes. 
OFF (4mA) or 
OUT1 low   
limit value 
OFF (4mA) or 
OUT1 low limit
value 
OFF or 
OUT2 low limit 
value 
OFF or 
OUT2 low limit 
value 
 
ON (20mA) or 
OUT1 high   
limit value 
ON or 
OUT2 high limit 
value 
 
Underscale 
Measured value 
has dropped below 
Indication range low 
limit value. 
"
" flashes. 
OFF (4mA) or 
OUT1 low   
limit value 
OFF (4mA) or 
OUT1 low limit
value 
OFF or 
OUT2 low limit 
value 
OFF or 
OUT2 low limit 
value 
Only for DC input and DC current output type, [Output status selection when input abnormal] is 
available. For other inputs and outputs except for DC input and DC current output, the output status 
will be the same one as when OFF is selected during [Output status selection when input abnormal]. 
For manual control, the preset MV (manipulated variable) is outputted. 
Power
Insulation
Power
supply
A1
CPU
CT
input
Output
Input
EVT (A2, Heater burnout
alarm) or OUT2
15
5
4
3
9
8
1
2
12
7
6
11
10
13
14
Commu-
nication