UA964801 - User manual
User manual - UA964801
75
Modbus
Address Description
Read
Only
Reset
value
1020
Hold by serial
0 = Active analogue input
1 = Analogue input in Hold
0 = Active analogue input
1 = Analogue input in Hold
R/W
0
1021
Tare zero AI (write 1)
R/W
0
1022
Totalizer reset (write 1)
R/W
0
1023
Peaks reset (write 1)
R/W
0
1024
Sum total (write 1)
R/W
0
1025
“Total sum” reset (write 1)
R/W
0
2001
Parameter 1
R/W
EEPROM
. . .
. . .
2150
Parameter 150
R/W
EEPROM
4001
Parameter 1*
R/W
EEPROM
. . .
. . .*
4150
Parameter 150*
R/W
EEPROM
* Parameters modified using serial address 4001 to 4150, will be stored on eeprom only after 10s
since last writing of one parameter.
10
Configuration
10.1 Modifying configuration parameters
For configuration parameters see par. 11
Press
Display
Do
1
Configuration
Shows 0000 with the 1
st
digit
selected.
2
and
Changes the selected digit
and moves to the next one
using
and moves to the next one
using
.
Enter password 1234
3
Sel
to confirm
Shows the names of the
parameter groups.
parameter groups.
4
and
Scroll up / down the
parameter groups.
parameter groups.
5
Sel
to enter the
parameter
group
Shows the parameters of the
selected group.
selected group.
Press
and
to select
parameter to be modified.
6
Sel
to enter
the
parameter
modification
Shows all parameter possible
selections or the parameter
numeric value.
selections or the parameter
numeric value.
Press
and
to modify
parameter. For numeric
parameters, pressing
parameters, pressing
it
is possible to modify digit-
to-digit. Press
to-digit. Press
Sel
to confirm
modification. Press
to exit
without modify.
10.2 Loading default values
Enter password 9999 to restore factory settings of the device.