Phoenix Contact 2701027 NLC-050-024D-06I-04QTP-00A nanoLine Base Unit 24ßV/DC / PNP 2701027 Datenbogen

Produktcode
2701027
Seite von 184
General Programming Techniques
2373_en_B
PHOENIX CONTACT
3-11
“Parity” selects the data parity from the drop-down list. Valid values are “None”, “Odd”, 
and “Even”.
“Watchdog” permits entry of a value, or use the spin buttons to set the watchdog timer. 
Valid values are from 0.0 to 25.5 seconds. A value of 0.0 disables the watchdog timer. 
If the time-out is exceeded after executing a command, the nanoLC issues a fault as 
defined in the “Fault” drop-down list.
“Fault” defines handling for faults. Available selections are:
“Fault” sets a fault condition and stop execution
“Warning” sets a warning condition and continue execution
Configuring the Real-Time Clock Option
The real-time clock option is available in the “Slot #2” drop-down list. Selecting this option 
displays the “Configure RTC” dialog box (Figure 3-7).
Figure 3-7
The “Configure RTC” dialog box
The “Configure RTC” dialog box has the following parameters:
“Date Format” defines the date format using the drop-down list. Choices are Day-
Month-Year (European), Month-Day-Year (US), and Year-Month-Day (International).
“Daylight Savings” used to select one of three options for handling Daylight Savings 
time. Available options are:
“None”
“U.S.”
“European” (selecting this option enables the “EU Time Zone” fields)
“EU Time Zone” has drop-down to select “Greenwich Mean Time”, “GMT +01:00”, and 
“GMT +02:00”. In addition, there is a browse (...) button that displays a selection dialog 
to set the EU time zone based on sample cities in the zone.
“Fault” provides choices for handling faults are:
“Fault” sets a fault condition and stop execution
“Warning” sets a warning condition and continue execution