Siemens SPS starter kit 6ED1057-3BA00-0AA8 12 Vdc, 24 Vdc 6ED1057-3BA00-0AA8 Datenbogen
Produktcode
6ED1057-3BA00-0AA8
Reference material
5.3 Special functions
LOGO!Soft Comfort Online Help
308
Operating Instructions, 06/2014
5.3.6.2
Pulse relay
Short description
The output is set and reset with a short one-shot at the input.
Connection
Description
Input Trg
You switch output Q on or off with a signal at input Trg (Trigger) input.
Input S
A one-shot at input S (Set) sets the output to logical 1.
Input R
A one-shot at input R (Reset) resets the output to logical 0
Parameter
Selection:
RS (input R priority), or
SR (input S priority)
Retentivity set (on) = the status is retentive in memory.
Retentivity set (on) = the status is retentive in memory.
Output Q
Q is switched on with a signal at Trg and is reset again at the next Trg pulse, if
both S and R = 0.
0BA0-0BA3:
The special function does not have an S input and priority preselection.
The following applies to output Q:
The following applies to output Q:
Q is switched on with a signal at Trg and is switched off again with the next
signal at Trg or R.
Timing diagram