Siemens SPS starter kit 6ED1057-3BA10-0AA8 6ED1057-3BA10-0AA8 Datenbogen

Produktcode
6ED1057-3BA10-0AA8
Seite von 344
LOGO! functions 
 
4.4 Special functions list - SF 
 
LOGO! 
238
 
Manual, 06/2014, A5E33039675 
 
Functional description 
This function fetches the analog input signal according to both the set sampling time St and 
the number of samples Sn and outputs the average value. A signal at R sets AQ to 0.  
Setting the Par parameter 
View in programming mode (example):