Wr Rademacher DuoFern 16234511 Wireless blind cord winder Flush mount 16234511 Datenbogen

Produktcode
16234511
Seite von 88
53
EN
18.3  Automatic dusk function; brief description
The automatic dusk function causes the roller shutters to 
close automatically to the lower end point or configured 
ventilation position. 
You can choose between two automatic dusk 
functions:
 
Automatic dusk function with Astro programme 
= switching time mode [ ASTRO ]
 
Automatic dusk function with light sensor 
= switching time mode [ SENSOR ]
Automatic dusk function with Astro 
programme
Automatic dusk function with connected 
light sensor
At twilight, the roller shut-
ters will lower to the lower 
end limit or configured 
ventilation position after 
approx. 10 seconds. The 
roller shutters will open 
again once the configured 
opening time is reached 
or in the event of a manual 
command.
The required twilight limit is configurable.
NOTE 
The  automatic  dusk  function  via  light  sensor  is  only 
executed once per day.
Mounting the light sensor  
(see page 56, Automatic solar function)
The twilight time is recalcu-
lated every day based on the 
geographical  location  and 
the current date (defined by 
the configured postcode). 
Configure a custom offset period
An offset can be configured between -60 and +60 minutes 
in order to customise the calculated dusk time to your 
personal preferences. This means that it is not necessary to 
continuously readjust the closing time throughout the year. 
A light sensor is not used for this function.