QNAP TS-231 Benutzerhandbuch

Seite von 344
137
During a power loss, the NAS will wait for the specified time you enter in the "UPS
Settings" before powering off or entering auto-protection mode.
If the power restores before the end of the waiting time, the NAS will remain in operation
and cancel its power-off or auto-protection action.
Once the power restores:
If the NAS is in auto-protection mode, it will resume to normal operation.
If the NAS is powered off, it will remain off. 
Diffe re nc e  be twe e n a uto- prote c tion m ode  a nd powe r- off m ode
M ode
Adv a nta ge
Dis a dv a nta ge
Auto-protection
mode
The NAS resumes after
power recovery.
If the power outage lasts
until the UPS is turned off,
the NAS may suffer from
abnormal shutdown.
Power-off mode
The NAS will be shut down
properly.
The NAS will remain off after
the power recovery. Manual
power on of the NAS is
required.
If the power restores after the NAS has been shut down and before the UPS device is
powered off, you may power on the NAS by Wake on LAN* (if your NAS and UPS device
both support Wake on LAN and Wake on LAN is enabled on the NAS). If the power
restores after both the NAS and the UPS have been shut down, the NAS will react
according to the settings in "System Settings" > "Power Recovery". 
*This feature is not supported by TS-110, TS-119, TS-210, TS-219, TS-219P, TS-410,
TS-419P, TS-410U, TS-419U, TS-112, TS-212, TS-412, TS-412U. Please visit http://
www.qnap.com for details.