Testing Internet Access
 
Start a PC or Notebook, which is connected to one of the guest ports, and 
launch a Web browser. Then open a Web site such as  
http://www.intellinet-network.com. 
If GuestGate has Internet access, you will see GuestGate’s welcome page.  
 
 
 
Click “continue” and you will then be forwarded to the Web page you originally 
entered in the Web browser’s address bar. 
 
 
Accessing the Administrator Web Interface from the Host 
Network 
Access to the Web administrator interface is only possible when connecting to 
GuestGate via the Host port.  
Connect to the router (DHCP Server) in your network and open the DHCP client 
log of the router. Connect GuestGate’s Host port to one of the router’s LAN 
ports and power-on GuestGate. Wait about 30 seconds, and then refresh the 
DHCP client log in the router. The last entry (the newest) belongs to GuestGate. 
Launch your Web browser and open the IP address shown in the DHCP client 
log. You will then see the Administrator Web interface.  
The default password is 1234
If this procedure does not work you can configure your PC with a static IP 
address of 192.168.2.xxx, disconnect GuestGate from the router and connect 
your computer directly to the host port. Power-on GuestGate and wait about 
one minute, then open GuestGate’s default IP address http://192.168.2.1 with 
the Web browser.  
 