Scala Fever thermometer SC33TM 01016 Datenbogen

Produktcode
01016
Seite von 1
Digital pacifier thermometer SC 33 TM 
 
 
 
 
 
 
 
 
 
 
 
 
                       Instructions for use 
 
 
Special features: 
The digital pacifier thermometer
 
 is a maximum thermometer, i.e. 
the  highest  temperature  is  displayed  after  only  90  seconds.  The 
most recent measured value is always saved.  
 
Safety instructions: 
 The thermometer is not suitable for use as a pacifier. 
 The thermometer is suitable exclusively for oral measurement of 
the body temperature of babies .  
 The thermometer can not be opened and the battery cannot be 
changed for safty reasons. 
 
Operating manual: 
Press  the  I/O button  to  switch  on.  A  short  signal  tone  shows  that 
the device is in the "switched on" condition. A segment test takes 
place simultaneously (checks all display segments and carries out 
an internal function test (see under "Function test")).  
 
After this, if the temperature measured by the temperature sensor 
is less than 32°C, the display shows an "L“ and "°C“. After around 
one  second, the "°C“   starts  to  blink.  The  „L“  stands  for low  (less 
than 32°C). 
 
The  current  temperature  is  continuously  displayed  during 
measurement, and the "°C" blinks during the entire measurement 
time. The measurement is completed after around 90 seconds. 
 
After  the  measurement  is  completed,  the  temperature  value 
measured  remains in  the  display  until  the pacifier  thermometer  is 
switched off. To turn the device off after use, press the I/O button 
briefly. The signal tone will again be sounded. If the device is not 
switched off, a signal tone is sounded after around 8 minutes and 
the device then switches off automatically. 
 
Display of last measured value: 
If you keep the I/O button pressed for longer than three seconds, 
the last measured value will be shown in the display. As soon as 
you  release  the  I/O  button,  the  device  is  ready  to  take 
measurements.  
 
 
 
 
 
 
Function test: 
The  thermometer  is  checked  for  correct  functioning  automatically 
every time it is switched on. All segments are displayed, and then  
L°C.  If  a  failure  (measurement  inaccuracy)  is  recognised,  "ERR“ 
(Error) is shown in the display. 
 
Important: 
The readings displayed by the thermometer may be too low under 
some conditions (e.g. if the child is crying or persistently breathing 
through  his  mouth).  Therefore,  in  case  of  doubt,  or  if  there  are 
signs  of  fever  (reddening  of  skin,  sweating,  agitation, 
unwillingness  to  drink),  please  always  perform  a  follow-up  rectal 
measurement if the result is more than 38,5°C. 
 
Battery symbol: 
If  the  battery  symbol  ” 
  ”  displayed,  the  life  time  of  the 
thermometer  is  over.
 
The  battery  cannot  be  changed  for  safty 
reasons. 
 
Measurement checks: 
Checking  the  accuracy  of  the  pacifier  thermometer  is  not 
necessary in most cases.  If you require a measurement check (at 
your  expense),  please  send  the  pacifier  thermometer  to  our 
customer  service  address.  Please  make  sure  it  is  well-packaged 
and that the correct postage stamps are applied. 
 
Cleaning and disinfection 
Please  only  use  an  alcohol  pad.  Alcohol  pads  can  be  purchased 
from any dispensing chemist.  
We  recommend  the  use  of  Mucocit
-F2000  or  Helipur
Hplus  to 
disinfect  the  thermometer  when  it  is  being  used  in  medical 
facilities.  Both  are  effective  against  all  hospital-typical  pathogens 
and can be purchased from any dispensing chemist. 
 
Guarantee: 
We give a guarantee period of 2 years from the date of purchase. 
We  guarantee  perfect  design  of  this  article.  We  will  rectify  all 
material  or  manufacturing  errors  during  the  guarantee  period.  If, 
contrary to expectations, defects are found, please send the  
device  back  to  our  customer  service  department.  Please  enclose 
the  proof  of  purchase  and  a  description  of  the  defect  so  that  the 
problem can be rectified as soon as possible. 
The  guarantee  excludes  damages  caused  by  improper  handling, 
related to the battery or to the packaging. 
 
Disposal note                                                                                                
The disposal of batteries is regulated. Dispose of the thermometer 
as prescribed. i.e., at a collection point for electrical scrap. 
 
Referenced norms: 
The  device  has  been  certified  in  accordance  with  DIRECTIVE 
93/42/EU of 14th June 1993 relating to medicinal products. 
The  clinical  thermometer  9840  complies  with  the  requirements  of 
European norm EN 12470-3:2000.  
 
 
 
 
 
 
Specifications: 
Measuring range: 
32.0°C to 43.9°C 
 
Temperature below 32.0°C:  
 
display "L“ for low. 
 
Temperature above 43.9°C: 
 
display "H“ for high. 
Measurement accuracy: 
0.1°C between 35.5°C and 42.0°C  
 
at a surrounding temperature of  
 
18°C to 28°C. 
Self-test: 
Automatic internal check of test  
 
value 37.0°C.  
 
In case of deviation > 0.1°C, "Err“  
 
will be displayed. 
Display: 
3-digit liquid-crystal (LCD display). 
Battery display: 
The  
 shows when the battery is  
 
discharged. 
Storage temperature: 
0°C to 50°C 
 
 
K-Jump Health Co., Ltd.                                                         
SCALA Electronic GmbH 
Ruhlsdorfer Str. 95  
14532 Stahnsdorf, Germany  
 
Service client 
SES GmbH 
Ruhlsdorfer Str. 95  
14532 Stahnsdorf, Germany  
 
Explanation of symbols 
 
 
 
 
 
 
 
 
 
 
 
 
Rev. 18/12/2012/GB