EL-2635 Repeater & Programming keypad – Repeater & Programierbedienteil – Repeteur & Clavier –
 
Repeater & Keypad  
Conrad No: 1276483 & 1276484 
Connect  the  Programming  Keypad  (EL2635-P)  to  the  Programming  
Keypad  (EL2635-P) connector. 
Note:  The  Programming  Keypad  (EL2635-P)  is  not  able  to  operate  on 
battery  power only.
 
8.  Test  the  repeater  from  the  required  mounting  location  before  permanently 
mounting the unit. 
9.  Mount the base to the wall using four screws and replace the front cover. 
 
 
 
When the tamper switch is open, the bi- 
color  LED provides indication regarding 
repeater  transmission  and  reception  as 
an aid during the installation procedure 
– see Table 1. When the tamper switch 
is  closed,  the  bi-color  LED  provides 
indication regarding power status 
– see 
Table 2
 
 
 
Table 1: LED Indication (Tamper Open) 
 
LED Indication 
Description 
Steady Green 
AC & Battery OK 
Flashing Red 
AC Loss 
Flashing Orange 
Low Battery 
Table 2: LED Indication (Tamper Closed) 
 
REGISTERING THE REPEATER TO 
THE CONTROL PANEL
 
For the control panel to recognize the repeater, you 
must register the repeater to the control panel. 
To register the repeater to the control panel: 
1. 
Set  the  control  panel  to  Registration  mode 
as follows: 
 
From the Programming menu, select 
Devices, Repeaters [914]. 
 
Select the repeater you want to register 
(1-4). 
 
From the 
repeater’s sub-menu, select 
Register [#1]. 
2. 
Send  two  Status  transmissions  from  the 
repeater as follows: 
 
On the Programming Keypad (EL2635-P), 
press ... until 5. STS Transmit appears on 
the display. 
 
Press ./. 
 
Press ./ again. 
 
 
 
 
 
 
 
Figure 3: LCD rogramming 
Keypad (EL2635-P) 
LED Indication 
Description 
Flashing Green 
Signal Reception 
Flashing Red 
Signal Transmission