Panasonic LC-R1233P, 12V Ah lead acid battery LC-R1233P Datenbogen

Produktcode
LC-R1233P
Seite von 19
32
Valve Regulated Lead-Acid Batteries
33
Valve Regulated Lead-Acid Batteries
LC-QA Series – Trickle Design Life 15 Years
Model Number
Nominal 
Voltage 
(V)
Rated Capacity 
(Ah)
Dimensions (mm)
Mass
approx.
(kg)
Page
VdS N°
Length
Width
Height
Approx.
Total Height
LC-QA06210TP
6
210
407
173
210
250
36.5
126
LC-QA1224AP
12
24
165
125
175
175
10.0
128
LC-QA1242P/AP
12
42
197
165
175
180
16.0
130
LC-QA1270P
12
70
350
166
175
175
23.5
132
LC-QA12110TP
12
110
407
173
210
236
36.0
134
*
1
 This battery is also available with a flame retardant battery case resin (UL94 V-0).  
*
2
 Trickle Design Life 6 – 9 Years.  
*
3
 Trickle Design Life 10 – 12 Years.
Model Number
Nominal 
Voltage 
(V)
Rated Capacity (Ah)
Dimensions (mm)
Mass
approx.
(kg)
Page
VdS N°
20 hour rate
Length
Width
Height
Approx.
Total Height
LC-X1220P/AP
*
1
12
20
181
76
167
167
6.6
82
LC-X1224PG/APG
12
24
165
125
175
179.5/175
9.0
84
G198049
LC-X1228P/AP
*
1
12
28
165
125
175
179.5/175
11.0
86
LC-X1238PG/APG
12
38
197
165
175
180/175
13.0
88
G100002
LC-X1242P/AP
*
1
12
42
197
165
175
180/175
16.0
90
LC-X1265PG
12
65
350
166
175
175
20.0
92
G199090
LC-X1275P
*
1
12
75
350
166
175
175
24.0
94
LC-XB12100P
*
1
12
100
407
173
210
236
37.0
96
LC-X12120P
*
1
12
120
407
173
210
236
37.0
98
VdS
LC Series – Trickle Design Life 10 – 12 Years
Model Number
Nominal 
Voltage 
(V)
Rated Capacity (Ah)
Dimensions (mm)
Mass
approx.
(kg)
Page
VdS N°
20 hour rate
Length
Width
Height
Approx.
Total Height
LC-CA1212P
12
12
151
98
94
100
3.8
100
LC-CA1215P
12
15
151
98
94
100
4.2
102
LC-CA1216P
12
16
151
98
99
105
4.7
104
LC-XC1222P
12
22
181
76
167
167
6.6
106
LC-XC1228P
12
28
165
125
175
179.5
10.0
108
LC-XC1238P
12
38
197
165
175
179.5
15.0
110
LC Series – Cycle Long Life
11 |  Battery Index
UP-RW / PW Series – Trickle Design 6 – 9 and 10 – 12 Years
Model Number
Nominal 
Voltage 
(V)
Rated Power (W)
Dimensions (mm)
Mass
approx.
(kg)
Page
VdS N°
10 minute rate
Length
Width
Height
Approx.
Total Height
UP-RW0645P
*
1, 2
6
135
151
34
94
100
1.3
112
UP-RW1220P
*
1, 2
12
120
140
38.5
94
100
1.4
114
UP-RW1228P
*
1, 2
12
200
151
64.5
94
100
1.9
116
UP-RWA1232P1/P2
*
1, 2
12
192
151
51
94
100
2.0
118
UP-RW1236P
*
1, 2
12
224
151
64.5
94
100
2.1
120
UP-RW1245P
*
1, 2
12
270
151
64.5
94
100
2.6
122
UP-PW1245P
*
3
12
270
151
64.5
94
100
2.6
124
VdS
VdS
VdS
12 |  Standards
Product Standards
Alarm security market / VdS approved batteries
UL Standard  
All our VRLA batteries are in compliance with UL 1989 
(Standby Batteries) – file number MH 13723. UL 1989 re-
quires that the battery is free from the hazard of bursting, 
that is, when the battery is overcharged the vent valve opens 
to release internal pressure.
JIS (Japan Industrial Standard)  
All our VRLA batteries are in compliance with JIS C 8702 
(almost harmonized with IEC 61056).
Factory Standards
ISO 9001 / ISO 14001
Quality Management System (ISO 9001) defines what the 
organization does to ensure that its products or services 
satisfy the customer’s quality requirements and comply with 
any regulations applicable to those products or services. 
ISO 14000 is primarily concerned with “environmental ma  n-
agement”. In plain language, this means what the organiza-
tion does to minimize harmful effects on the environment 
caused by its activities.
OHSAS 18001
OHSAS 18001 is an Occupation Health and Safety Ass ess-
ment  Series for health and safety management systems. 
It is intended to help organizations to control occupational 
health and safety risks. It was developed in response to 
widespread demand for a recognized standard against 
which to be certified and assessed.
Other applicable Standards
Following documents are established by consensus and 
 
approved by a recognized body, that provides, for common 
and repeated use, rules, guidelines or characteristics for 
 
activities or their results, aimed at the achievement of the 
optimum degree of order in a given context.
NOTE:  Standards should be based on the consolidated 
 
results of science, technology and experience, and aimed at 
the promotion of optimum community benefits.
IEC standards cover a vast range of technologies from power 
generation, transmission and distribution to home appliances 
and office equipment, semiconductors, fibre optics, batteries, 
solar energy, nanotechnology and marine energy as well as 
many others.
IEC standards are also being adopted as harmonized stand-
ards by other certifying bodies such as BSI (Great Britain), 
CSA (Canada), UL & ANSI/INCITS (USA), SABS (South Africa),  
SAI (Australia), SPC/GB (China), DIN (Germany) and JIS (Japan). 
IEC standards harmonized by other certifying bodies generally 
have some noted differences from the original IEC standard.
Model Number
Nominal 
Voltage 
(V)
Rated
Capacity
(Ah)
 VdS N°
Country
of origin
LC-R121R3PG
12
1,3
G196049
China
LC-R122R2PG
12
2,2
G188151
China
LC-R123R4PG
12
3,4
G191053
China
LC-R127R2PG
12
7,2
G193046
China
LC-RA1212PG
12
12
G100001
China
LC-XD1217PG/APG
12
17
G104101
China
LC-X1224PG/APG
12
24
G198049
China
LC-X1238PG/APG
12
38
G100002
China
LC-X1265PG
12
65
G199090
China
VdS