Panasonic Door switch 250 Vac 5 A Tappet momentary AZC11113AJ IP40 1 pc(s) AZC11113AJ Datenbogen

Produktcode
AZC11113AJ
Seite von 2
SAFEGUARDED BY MAGNET
BUILT-IN DETECTOR SWITCH
54
Metal plate
4.2 dia.
14.4 dia.
50
60
12.7
13
1.6
M3.5 terminal screw
31
Magnelimit
4.5
3.8 dia.
9.4
15
(72.7)
Release position (R.P.) 4 max.
Pretravel (P.T.) 1.8 max.
7.5
–0.1
+0.2
4.2
R2.1
R2.1
52
±0.15
60
38.2
11
43.8
Magnet
2
.177
.079
.150
1.220
.591
.370
.165
.063
.512
1.969
2.362
±.006
2.047
–.004
+.008
.567
.500
.165
.295
.433
1.504
11.8
±0.15
±.006
.465
1.724
(2.862)
2.362
Product name
Specifications
Contact construction
Case color
Sustainable weight sustainability
Packaging
AZC11013Y
3kg type (29.4N {3kgf})
(Note: 1)
Yellow
1a
(ON when gate is closed)
1b
(ON when gate is open)
Metal plate
Magnelimit 1 Form A
Magnelimit 1 Form B
Options
Brown
Gray
Yellow
Brown
Gray
AZC11013YP
Blister pack
AZC11013A
AZC11013AP
Blister pack
AZC11013H
AZC11013HP
Blister pack
AZC11113Y
AZC11113YP
Blister pack
AZC11113A
AZC11113AP
Blister pack
AZC11113H
AZC11113HP
AZC1801
Blister pack
Metal plate (13mm 
 60mm  1.6mm 
.512inch 
 2.362inch  .063inch
)
Part No.
Magnelimit
FEATURES
1. A switch that makes electrical con-
struction possible at 100V power.
2. The built-in magnet safeguards check-
ing of the facility cover and gate.
3. Built-in switch with accurate ON/OFF
detection.
4. Combination of magnet (support) and
limit switch (detection) saves on both
construction and space.
5. Two types of contact: 1a (ON when
gate is closed), and 16 (ON when gate is
open.)
6. The unit case comes in three colors:
Yellow, brown, and gray.
7. The product comes with three different
types of weight sustainability: 1kg, 3kg,
and 5kg.
PRODUCT TYPE
SPECIFICATIONS
1. Ratings
OUTPUT CIRCUIT DIAGRAM
Notes:1. The unit comes with an metal plate enclosed.
2. The blister pack type comes with 1 metal plate and 4 screws (2 long, 2 short) enclosed.
3. Weight sustainability also comes in 1kg and 5kg types. Specify when ordering by replacing “3” with “1” for the 1kg type, and “5” for the 5kg type at the end of the part No.
Guidance load
Lamp load
Resistance load
5A
125V AC
1.5A
3A
Load type
Rated voltage
5A
250V AC
3A
5A
30V DC
Operating force (O.F.) (N{gf})
3.43  {350} max.
Return force (R.F.) (N{gf})
0.49  {50} min.
Pretravel (P.T.)
1.8mm 
.071inch
max.
Movement differential (M.D.)
0.2  to 0.8
Release position (R.P.)
4.0mm 
.157inch
max.
1.5A
Notes:1. Inductive load is a minimum 0.4 (AC) and time duration is maximum 7ms (DC).
2.  Lamp load has 10 times the inrush current.
3.  Minute load ratings: 5mA 6V DC, 1mA 24V DC.
2. Switch operating features
Electrical
capabilities
Life
Protective capabilities
Insulation
resistance (initial)
Min. 100Ω (measured at 500V DC insulation resistance)
Voltage
resistance
Contact distance: AC 1000V/1 min. (initial)
Distance between each pin and uncharged metal parts: AC 2100V/1 min.
Distance between each pin and earth: AC 2100V/1 min.
Mechanical life
Min. 100 thousand times (ON/OFF frequency 60 times/min.)
Electrical life
Ambient temperature
Min. 50 thousand times (resistance load AC 250V 5A)
Min. 30 thousand times (lamp load AC 125V 1.5V)
ON/OFF frequency 20 times/min.
IP40
Usage
conditions
Sustainability
(when using the enclosed metal plate)
–20 to +80°C 
–4 to 176°F
(but not in a frozen environment.)
Ambient humidity
Tolerable operating
frequency
Max. 95% RH
Mechanical: 60 times/min.
Electrical: 20 times/min.
1kg (9.8N {1kgf}), 3kg (29.4N {3kgf}), 5kg (49N {5kgf})
3. Capabilities overview
DIMENSIONS  
mm 
inch
1 Form A type
1 Form B type
04/2005