INA209 Software Overview
www.ti.com
4.4.6
Critical Fault Tab
The Critical Fault tab allows complete configuration of the Critical Fault feature on the INA209. The Critical
Fault feature is an analog path that will trigger when the shunt voltage exceeds a specific level. The level
is set by the Critical DAC+ and the Critical DAC– controls. Hysteresis, polarity, latch enable, and output
enable options can also be set. See the
4.4.7
SMB Alert Tab
The SMB Alert tab sets the Alert mask register. This register configures the INA209 to allow some events
to cause an SMB Alert, while preventing (or masking) other events from causing an Alert. This tab allows
the Alert output to be enabled or disabled.
4.4.8
Scaling Overview Tab
This tab allows you to see how the mathematics work in the INA209. Specifically, this tab shows how the
current and power values are computed using the full-scale calibration register.
4.4.9
Graph Tab
The graph tab displays bus voltage, shunt current, and power versus time when the software is in
continuous convert mode.
4.4.10
Registers Tab
This tab allows reading and editing of all the registers in the INA209. All the previous tabs will affect the
register listing. For example, changing the A/D configuration in tab 2 will affect Register 0 in the register
list. It is also true that changing Register 0 will update the A/D configuration on tab 2. Thus, the graphical
representation and register representation affect each other.
22
INA209 Evaluation Module
SBOU055A – February 2008 – Revised February 2010