Tansun Quartz IR radiator 2000 W 12 m² White 102512 IP RG Datenbogen

Produktcode
102512 IP RG
Seite von 4
4. Disconnect the emitter from the connector blocks by unscrewing the screws highlighted above in Fig. 2. 
 
 
5. Unscrew the four screws (see Fig. 3) from the end cap and remove from the heater body. Repeat at opposite end. 
 
 
6. Slide out the side covers from both ends and slide out the guard from either end (Fig. 3 & 4 shows side covers with lenses for models with lights). 
R e p l a c i n g   t h e   E m i t t e r  
 
If  you  are  in  any  doubt  about  following  the  procedure  below,  please  contact  us  for  technical  assistance.  The  mains  power  should  be        
disconnected  before  any  attempts  are  made  to  replace  the  emitter.  The  following  should  be  carried  out  with  compliance  to  latest  IEE         
regulations. Please read the notes on the previous page with regards to handling and buying a  replacement emitter before proceeding. 
 
 
1.  Ensure  the  heater,  emitter  and  on  models  with  lights  the  bulbs  are  cool  and  the  power  supply  is  disconnected  by  removing  the  plug(s)  from  the 
socket outlet. 
 
 
2. Providing there is reasonable access and you are standing on a safe and stable platform, the emitter can be replaced with the heater still mounted. 
Otherwise, remove the heater from its mounting and work on a safe,  flat surface. 
 
 
3. Remove the screws from the terminal box (Fig. 1) and lift off the cover. 
Fig. 3 
Fig. 4 
Fig. 1 
Fig. 2 
H a n d l i n g   t h e   R e p l a c e m e n t   E m i t t e r  
 
Your  new  emitter  should  not  be  handled  with  bare  hands.  Remove  finger  marks  with  a  soft  cloth  and  methylated  spirits  or  rubbing  alcohol.  Finger 
marks will burn into the quartz glass causing premature emitter failure. 
Y o u r   R e p l a c e m e n t   E m i t t e r  
 
It is very important that your replacement emitter is exactly the same as the one it was supplied with. Failure to fit the exact same type could cause the 
heater to fail or even become dangerous especially when used in an outdoor environment. 
Please contact Tansun Limited to purchase your replacement emitter and state the model number of the heater you wish to fit the emitter to. 
7.  Firstly  remove  the  two  screws  as  highlighted  on  the  right  of  Fig.  5  to  remove  the  side  reflector  bracket.  If  your  heater  is  a  model  with  lights  you 
should then remove the two screws holding the bulb plate as highlighted on the left of Fig. 5 to allow the bulb plate to be lifted. Repeat at opposite end. 
8. Starting at the end where the emitter wires are fed through the gasket into the terminal box, if the heater has lights hold the bulb plate out of the way 
(Fig. 6) or if it is a heater only, the wires will be clearly visible, gently pull the emitter wires through the body of the heater so the wires exit the terminal 
box (Fig 6). 
9. At the opposite end of the heater, if the heater has lights hold the bulb plate out of the way (Fig. 7) or if it is a heater only the wire will be clearly  
visible in the feeder tube, gently pull the emitter wire out of the tube. 
 
 
10. Pull the emitter wires through the side reflector bracket and then one at a time pull the spring clips back and lift up the  ceramic caps of the emitter 
to remove it from the heater. 
 
 
11. The emitter should now be removed from the heater. Refit the new emitter in reverse order ensuring the ceramic caps are correctly seated in the 
emitter holders, no wires are trapped and all screws are fully tightened. 
Fig. 7 
Fig. 8 
Fig. 5 
Fig. 6