Utica Boilers UB90-100 Servicehandbuch

Seite von 1
 
2201 Dwyer Ave. ● P.O. Box 4729  ● Utica, NY 13504-4729 ● Ph: 315-797-1310 ● Fax: 315-797-3762 ● E-Mail: info@ecrinternational.com ● Web: 
www.ecrinternational.com
 
 
 
 
 
 
 
 
 
 
 
   
 
      BULLETIN NO. 5282013-UB 
 
 
 
DATE: May 28, 2013                                                         
 
PRODUCT: Utica Boiler UB90-100 II / III               
 
FROM: Technical Service Department 
 
TITLE: Direct Spark Ignition (DSI) to Hot Surface Ignition (HSI) Upgrade 
 
MODELS AFFECTED: 
 
UB90-50 Series II  
UB90-75 Series II  
UB90-100 Series II / III 
 
 
SERIAL NO. RANGE:
  
First four digits: 3412 – 5212  (34
th
 - 52
nd
 week / 2012) 
 
 
 
 
                   0113 – 0313  (  1
st
 - 3
rd
 week / 2013)  
 
SITUATION:
 
Utica Boilers upgrade from Direct Spark Ignition (DSI) to Hot Surface Ignition (HSI) on all Series II and Series 
III boilers manufactured from August 20, 2012 – January 18, 2013.  
 
SOLUTION:
  The below kits are available thru the distributor normal purchase order channels for field upgrade to the 
aforementioned model boilers.  These kits will be available to qualified installers to upgrade these specific boilers from DSI to a 
HSI ignition system.   
       
 
 
 
 
 
 
Kit  
Model 
Fuel  
Updates Series Listed 
 
 
Number  
 Description  
Type  
 Below to Series IV  
 
 
550002825 
UB 90-50   
Nat/LP 
Series II 
 
 
550002826 
UB 90-75  
Nat only  
Series II 
 
 
550002828 
UB 90-75  
LP only  
Series II 
 
 
550002827 
UB 90-100  
 Nat / LP 
Series III 
 
 
550002829 
UB 90-100  
Nat only 
Series II 
 
 
 
 
 
 
 
 
For complete kit Instructions please see instruction sheet # 240010144 
For any additional information on this series upgrade contact ECR International Inc, Technical Service at 1.800.241.5501 
Technical
 Bulletin