Portable Dryer Troubleshooting
36
Meter Roll Sensor Wiring
1997 Dryers have only 1 meter roll board.
Remove one meter roll board and tie the 
2   T-3 wires together.
Board
Meter Roll
Board
Meter Roll
12 Volt +
12 Volt -
12 Volt -
12 Volt +
Pulse
Pulse
T-2
T-1
T-3
T-2
T-1
T-3
METER ROLL SENSOR
J5-5
S2
S1
J5-12
J1-20
J5-9
J5-19
J5-16
J5-4
J7-8
J7-3
B1
J7-4
J9-16
J1-13
J4-12
J4-19
J1-19
J1-11
J1-9
J1-5
9
12
J5
16
19
J1-7
J5-8
J 1
J4
J3
J2
 Wiring Reference