BENDIX SD-23-7550 Benutzerhandbuch

Seite von 36
35
Attach the Actuator with new Nuts 
(self-locking EN ISO 7042) and torque tighten to 
133
+22
  ft.lbs. (180 
+30 
Nm).
Connect air hose, ensuring that hoses are correctly
connected.
Make sure that hoses are not twisted and that cha-
fing is not possible.
IMPORTANT!
during maintenance work, using a soap solution to check for leakage.  A 1 inch 
 Push park control valve in to release parking brake,
 and check for leakage.
Screw in Spring Brake Release bolt to maximum 
52 ft.lbs. (70 Nm).
13 Additional information
13.1 Service 
Video
A Video is available for additional
information.
Order number: RA-SB0002.EN Video (English)
RA-SB0002.FR Video (French)
RA-SB0002.PO Video (Portugese)
RA-SB0002.SP Video (Spanish)
13.2  Service Tool Kit ZB 9032
For service and repair work we recommend
our BendixTool Kit ZB 9032 II 37951/004EX, 
which contains all the necessary special tools.
13.3 Diagnostic 
Equipment 
For vehicles fitted with continuous 
potentiometer type wear sensors, 
Bendix Diagnostic Equipment may 
be used to ensure quick and simple 
measurement of wear at each caliper.
See sections 5.4 and 5.5.   
bubble in 1 minute is acceptable, otherwise repair/replace components as necessary.
Road test vehicle before returning to service. Test any air hoses or fittings reinstalled