B&B Electronics RS-232 to J1939 Converter CE 1939STB Benutzerhandbuch

Seite von 40
1939STB4600 Manual 
 
15 
 
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 
B&B Electronics Ltd – Westlink Commercial  Park – Oranmore, Galway, Ireland – Ph +353 91 792444 – Fax +353 91 792445 
 
 
Message Information 
 
 
 
The message information controls the action of the message. It also 
contains the header information that will be sent out on the J1939 bus. The 
bytes that control the message and are not transmitted to the bus are grayed 
in. Byte 5 and 6 are the message control bytes. They work together to control 
the message. The bit fields are set up in a two bit configuration as follows: 
NOTE:  Byte 11 covered on page 18. 
 
 
The bit values shown in gray are the only values valid for the setup 
of the 1939STB. 
Table 22.  J1939 Message Information 
Message Information 






10 

11 
95 
E7 0C 80  00 40  8C 
 
 
 
 
 
 
 
Table 23.  Two Bit Values for Byte 5 and 6 
Value of 2 bit field 
Function on write 
Function on read 
0 0  Reserved 
Reserved 
Reset element 
Element is reset 
Set element 
Element is set 
1 1  No 
change 
Reserved