Blodgett KLT-12G Benutzerhandbuch

Seite von 23
9
5.0  OPERATING INSTRUCTIONS
FRONT PANEL CONTROLS:
Power Switch
This switch turns the main power to the unit on and off.  It must be turned on to heat the kettle.
It should be turned off when the kettle will not be in use for long periods.
Thermostat
Selects the desired internal kettle operating temperature.  It also turns on the temperature 
light (red) and ignition light (green).
Temperature Pilot Light (Red)
When the kettle has reached set temperature, temperature light (red) will go off.
Ignition Pilot Light (Green)
Comes on with temperature light (red) and indicates ignition has occurred.  Should it not come
on with temperature light, this would indicate failed ignition or burnt out light.
Low Water Light (Amber)
All kettles are supplied with sufficient water in the pressurized jacket.  If at any time the water
level falls below that required for proper operation, the kettle will not heat and this light will
come on.  See “Adding Water” section of service instructions.
Pressure Gauge
The pressure gauge indicates the internal operating pressure of the kettle.
Sight Glass
The sight glass indicates the water level within the kettle jacket.
Pressure Relief Valve
The pressure relief valve is a safety device which prevents the internal kettle pressure from
exceeding 50 psi.  It should never be tampered with.