Bertazzoni 24 Cooktop 4-Burner Benutzeranleitung

Seite von 24
 
2
INDEX: 
Installation manual……………………………………..……………………………..pag.2 
Inserting the hotplate……………………………………………..…………………..pag.3 
Requirements……………………………………..……………………………….…..pag.3-4 
Attaching the hotplate……………………………………..………………………….pag.4 
Gas connection……………………………………..…………………………………pag.4-5-6 
Electrical connection……………………………………..……………………….…..pag.6 
Wiring diagrams……………………………………..…………………………….…..pag.6 
Instructions for assembly of load bearing bottom protection.…………………….pag.6-7 
Room ventilation…………………………………….…………………………………pag.7 
Location and venting…………………………………….…………………………….pag.7 
Replacement of nozzles……………………………………..………………………..pag.7 
Regulation of burners……………………………………………...………………….pag.8 
Service & maintenance instructions……………………………..…………………..pag.8 
User instructions……………………………………………..……………………….. pag.9 
Descriptions…………………………………………………………………………….pag.9 
Using burners……………………………………………………..……………………pag.9-10 
Cleaning the appliance……………………………………………..…………………pag.10 
 
 
Installation manual 
This appliance shall only be installed by an authorized person. This appliance shall be installed in 
accordance with the manufacturers installation instructions, IMPORTANT: this appliance must be 
installed in accordance with  the norms in force of the country concerned. 
The installation of this appliance must conform to local codes and ordinances. In the absence of 
local codes, Installations must conforms to American National Standards, National Fuel Gas Code 
ANSI Z223.1 – latest edition** or B149.1. 
If local codes permit, a flexible metal appliance connection with the new AGA or CGA certified 
design, max. 5 feet (1,5 m) long, ½” I.D. recommended for connecting this cooktop to the gas supply 
line. Do not bend or damage the flexible connector when moving the cooktop. The pressure regulator 
has ½” female pipe thread. You will need to determine the fitting required, depending on the size of 
your gas supply line, the flexible metal connector and the shutoff valve. 
The appliance, when installed, must be electrically grounded  in accordance with local codes or, in 
the absence of local codes, with the National Electrical Code, ANSI/NFPA 70. 
The appliance and its individual shutoff  valve must be disconnected from the gas supply piping 
system any pressure testing of that system at test pressure in excess of ½ psi (3,5 kPa). 
The appliance must be isolated from the gas supply piping system by closing its individual manual 
shutoff valve during any pressure  testing of the gas supply piping  system  at test pressures equal 
to or less than ½ psi (3.5 kPa). 
For use with a pressure regulator. The regulator supplied must be used with this appliance. 
The gas appliance pressure regulator must be set for the gas with which the appliance is used. 
This appliance can be used with Natural Gas and LP Gas. It is shipped from the factory adjusted for 
use with Natural Gas: CONVERSION FIXED ORIFICES ARE LOCATEDIN THE LITERATURE PACK 
SUPPLIED WITH THE UNIT. 
Injectors kit for the change of type of gas are contained inside the package jointly with the hob 
installation kit and Instruction booklet.  
The maximum inlet gas supply pressure incoming to the gas appliance pressure regulator is  20’’ 
water column (5 kPa) . 
The minimum gas supply pressure for checking the regulator setting shall be at least 1“ w.c. (249 Pa) 
above the inlet specified manifold pressure to the appliance (this operating pressure is 4” w.c.     
(1.00 kPa) for Natural Gas and 11” w.c. (2.75 kPa) for LP Gas). 
ATTENTION: A manual valve shall be installed in an accessible location in the gas line external to the 
appliance for the purpose of turning on or shutting off gas to the appliance 
WARNING: Do not use aerosol sprays in the vicinity of this appliance while it is in operation