PAR Technologies PARASTATION5 V5 Benutzerhandbuch

Seite von 98
36
ParaStation5 Administrator's Guide
The following five types of parameters within the Hardware environment will get a special handling from
the ParaStation daemon psid(8). These define different script files called in order to execute various
operations towards the corresponding communication hardware.
All these entries have the form of the parameter's name followed by the corresponding value. The value
might be enclosed by single or double quotes in order to allow a space within.
The values are interpreted as absolute or relative paths. Relative paths will be looked up relative to
InstallDir
. If one or more of the scripts are not defined, no corresponding action will take place
for this hardware.
startscript
Define a script called in order to startup the corresponding communication hardware. This script
will be executed when the daemon starts up or after a reset of the communication hardware.
stopscript
Define a script called in order to shutdown the corresponding communication hardware. This script
will be executed when the daemon exits or before a reset of the communication hardware.
setupscript
Define  a  script  called  in  order  to  set  special  parameters  on  the  corresponding  communication
hardware.
statusscript
Define  a  script  called  in  order  to  get  a  status  message  from  the  corresponding  communication
hardware. This is mainly used in order to generate the lines shown be the status 
counter
 directive
of the ParaStation administration tool psiadmin(1).
headerscript
Define a script called in order to get a header line for the status message produced by the above
discussed statusscript .
All  further  parameters  defined  within  a  Hardware  section  are  interpreted  as  environment  variables
when calling the above defined scripts. Again these parameters have the form of the parameters name
- interpreted as the environments variables name - followed by the corresponding value. The values
might be single strings not containing whitespace characters or enclosed by single or double quotes,
too.
The impact of the environment variables on the scripts of course depend on the scripts itself.
Various hardware types are defined within the template configuration file coming with the ParaStation
software distribution. These hardware types, the corresponding scripts and the environment variables
the scripts understand are briefly discussed within the following lines.
Shared memory will be used as hardware type for communication within a SMP
node. As there are no options for this kind of hardware, no dedicated section is
provided.
ethernet
Use classical TCP/IP communication over Ethernet via an optimized MPI implementation.
Since  TCP/IP  has  to  be  configured  before  ParaStation  starts  up,  the  corresponding  script
ps_ethernet  has  almost  nothing  to  do  and  hence  does  not  understand  a  single  environment