MRV Communications MR2228-S2C Benutzerhandbuch

Seite von 41
 
5
 
Table 1-2. System Status LEDs 
LED Condition 
Status 
On Green 
The unit’s internal power supply is operating 
normally. 
On Amber 
The unit’s internal power supply has failed. 
PWR 
 
Off 
The unit has no power connected. 
On Green 
The system diagnostic test has completed 
successfully. 
Flashing 
Green 
The system diagnostic test is in progress. 
Diag 
 
On Amber 
The system diagnostic test has detected a fault. 
Green 
A redundant power unit is attached and is in backup 
or active mode. 
Amber 
There is a fault in the redundant power unit. 
RPU 
 
Off 
There is no redundant power unit currently 
attached. 
Flashing 
Amber 
An initial power-on state during which the stack 
configuration is detected. 
Green 
This switch is acting as the Master unit in the stack.
Amber 
This switch is acting as a Slave unit in the stack. 
Stack 
 
Flashing 
Green 
When the user enters the light unit command in 
the CLI, the unit ID of each switch in the stack will 
be displayed by the port LEDs 1 to 8. 
Power Supply Receptacles 
There are two power receptacles on the rear panel of the switch. The standard