Behringer Ultrapar UP1200 Benutzerhandbuch

Seite von 8
6
ULTRAPAR UP1200 User Manual
3.1  Dismounting the lens 
◊ 
The lens gets very hot during operation of the spotlight, 
so let it cool down sufficiently before you attempt to 
dismount it!
Disconnect the spotlight from the mains and wait until it has 
cooled down
Place the spotlight on a flat and stable surface. Never mount or 
dismount the lens, while the spotlight is fi xed to a truss or stand
Remove the protective mesh
 (8)
: press its two spring shackles, 
then pull out the mesh
Directly in front of the lens, you will fi nd a movable metal 
clamp 
(4) 
attached to the lens ring
 (5)
. Turn the lens ring, 
until the metal clamp is located on the top side of the spotlight 
(directly below the locking bracket
 (13)
Tilt the front side of the spotlight forward by at least 45°
Push the movable metal clamp upward to dismount and pull out 
the lens
 (10)
3.2  Mounting the lens
Tilt the spotlight forward and turn the lens ring
 (5)
, until the 
movable metal clamp
 (4) 
is located on the top side of the 
spotlight (directly below the locking bracket
 (13)
Insert the lens with its rounded side towards the rear. 
The lower edge of the lens must be located behind the 
projecting elements
 (6) 
of the lens ring
Press the upper edge of the lens slightly towards the rear, 
until it locks in behind the metal clamp
 (4)
Installation of the protective mesh
 (8)
: Press the two spring 
shackles of the protective mesh and place it directly in front 
of the lens ring
 (5)
. There are two slots in the die-cast casing 
of your ULTRAPAR for the “feet” of the protective mesh. 
The two spring shackles must be located directly below 
the locking bracket 
(13)
4.  Color frame
The color frame 
(11) 
is used to hold color filters. Please observe the 
following instructions to install the color frame:
Detach the locking bracket
 (13) 
on the top side of the spotlight, 
by pushing it to the side. Then, open the bracket and tilt it 
towards the rear
Insert the color frame into the frame holders 
(9)
 and 
(12)
i.e. the outer guiding rail (with stops on three sides) on the 
front side of the ULTRAPAR
Push the locking bracket
 (13) 
to the side and move it down 
until it locks in
◊ 
Only use color filters with appropriate 
temperature resistance!
◊ 
Never use your ULTRAPAR without the protective mesh in 
combination with the colorframe because it prevents direct 
contact with the hot lamp surface. It also prevents pieces of 
broken glass from uncontrollably dispersing in the event of 
the lens being broken.
5.  Cleaning the reflector
Disconnect the spotlight from the mains and remove the 
lamp casing as described in chapter 2.1
Remove the color frame
 (11) 
(chapter 4), the protective mesh and 
lens 
(10) 
(chapter 3.1), so that the refl ector is easily accessible
Cleaning the reflector: Use oil-free compressed air or a soft, 
lint-free cotton cloth. Tenacious stains can be removed by 
adding some mild soap water, however, don’t forget to remove 
all soap water remnants as well
Remount the spotlight (see chapters 2.1 and 3.2)
◊ 
Never clean the reflector with commercial window cleaners, 
as the chemical substances contained in these agents can 
damage the reflector insert!
◊ 
Don’t use paper towels or other material with a rough 
surface to wipe the refl ector clean, so as to avoid scratches 
damaging the reflector surface.
◊ 
Avoid touching the reflector with bare hands. Oily finger 
marks can bake onto the glass surface and substantially 
lower optical quality. 
6.  Suspended installation
Use the mounting bracket
 (1) 
to attach your spotlight to a stand 
or truss. Always use M12 steel screws to fasten the spotlight. 
Your UP1200 must be secured with an additional safety steel cable . 
Use the steel cable fixed to the spotlight casing (eyelet 
(15)
).
Once the spotlight has been adjusted, it must be secured in place 
with the locking screw 
(14)
.
7.  Specifications
Power  
575 W max. (120 V / 240 V)
Max. room temperature  
Ta = 45°C
Max. temperature of  
Tmax = 175°C 
exterior surfaces 
Physical/Weight
Dimensions  
approx. 11 3/4 x 9 1/4" 
(Height x Diameter) 
approx. 300 x 237 mm
Weight  
approx. 10.8 lbs / 4.9 kg
BEHRINGER is constantly striving to maintain the highest professional standards. As a result of 
these efforts, modifi cations may be made from time to time to existing products without further 
notice. Specifi cations and appearance may differ from those listed or shown.