WHITE-RODGERS
1F89-11
Non-Programmable Electronic Digital
Heat Pump Thermostat
INSTALLATION AND
OPERATION INSTRUCTIONS
PART NO. 37-5741A
Replaces 37-5612B
9636
Operator: Save these instructions for future use!
ELECTRICAL DATA
Electrical Rating:
Electrical Rating:
20 to 30 VAC 50/60 Hz. or D.C.
0.05 to 1.5 Amps (Load per terminal)
1.5 Amps Maximum Total Load (All terminals
0.05 to 1.5 Amps (Load per terminal)
1.5 Amps Maximum Total Load (All terminals
combined)
THERMAL DATA
Setpoint Temperature Range:
Setpoint Temperature Range:
45
°
F to 90
°
F (7
°
C to 32
°
C)
Operating Ambient Temperature Range:
32
°
F to 105
°
F
Operating Humidity Range:
0 to 90% RH (non-condensing)
Shipping Temperature Range:
-40
°
F to 150
°
F
APPLICATIONS
For use with:
• Heat pump systems with up to two stages heat,
one stage cool
DO NOT USE WITH:
• Millivolt systems
• Systems exceeding 30 VAC and 1.5 amps
• 3-wire zoned hydronic heating systems
• Systems exceeding 30 VAC and 1.5 amps
• 3-wire zoned hydronic heating systems
SPECIFICATIONS
Your new White-Rodgers Digital Heat Pump Thermostat
uses the technology of a solid-state microcomputer to
provide precise temperature control. This thermostat of-
fers you the flexibility to set heating and cooling tempera-
tures that fit your needs.
uses the technology of a solid-state microcomputer to
provide precise temperature control. This thermostat of-
fers you the flexibility to set heating and cooling tempera-
tures that fit your needs.
Features:
• Simultaneous heat and cool temperature storage
• LCD continuously displays set point and room tem-
perature
•
°
F/
°
C convertibility
• Temperature range 45
°
to 90
°
F
• Eight terminals for single or two-transformer systems
• O/B terminal for heat pump systems
• Armchair Demonstration Capability
CAUTION
!
To prevent electrical shock and/or equipment
damage disconnect electric power to system at
main fuse or circuit breaker box until installation
is complete.
damage disconnect electric power to system at
main fuse or circuit breaker box until installation
is complete.
Do not use on circuits exceeding specified volt-
age. Higher voltage will damage control and
could cause shock or fire hazard.
age. Higher voltage will damage control and
could cause shock or fire hazard.
Do not short out terminals on gas valve or pri-
mary control to test. Short or incorrect wiring will
damage thermostat and could cause personal
injury and/or property damage.
mary control to test. Short or incorrect wiring will
damage thermostat and could cause personal
injury and/or property damage.
WARNING
!
This thermostat is intended for use with a 24-volt system;
do not use this thermostat with a millivolt or line voltage
system. If in doubt about whether your wiring is millivolt,
line, or low voltage, have it inspected by a qualified
heating and air conditioning contractor or electrician.
do not use this thermostat with a millivolt or line voltage
system. If in doubt about whether your wiring is millivolt,
line, or low voltage, have it inspected by a qualified
heating and air conditioning contractor or electrician.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical
codes and ordinances.
codes and ordinances.
This control is a precision instrument, and should be
handled carefully. Rough handling or distorting compo-
nents could cause the control to malfunction.
handled carefully. Rough handling or distorting compo-
nents could cause the control to malfunction.
PRECAUTIONS