INSTALLATION INSTRUCTIONS
Prepare Location
Before making cutouts, make sure there is proper clearance 
within the ceiling or wall for the exhaust vent.
When cutting or drilling into the ceiling or wall, do not 
damage electrical wiring or other hidden utilities.
Check that all installation parts have been removed from the 
shipping carton.
1. Disconnect power.
2. Determine which venting method to use: roof or wall exhaust.
3. Using 2 or more people, move the in-line blower motor 
system to the mounting location. 
Prepare for Mounting the In-line Blower System
The in-line blower system must be fastened to a secure structure 
of the roof, ceiling, wall, floor, or new or existing frame 
construction. The 4 holes on either the inlet (bottom) side or the 
outlet (top) side of the blower must be used to mount the in-line 
blower system to the structure.
NOTE: The mounting hole locations must span the studs. 
Additional stud framing may be required. Plywood may be used 
to span open areas between ceiling joists or roof rafters to aid 
installation. This structure must be strong enough to support the 
weight of the in-line blower system (50 lb [22.6 kg] min).
Prepare the In-line Blower System
1. Remove the 10 screws from the front cover of the in-line 
blower motor housing and set them aside.
2. Remove the front cover of the in-line blower motor housing 
and set it aside.
NOTE: To make the blower motor housing easier to mount, the 
blower motor assembly can be removed. If you do not want to 
remove the blower motor assembly, proceed to the “Installation 
of the In-line Blower System” section.
3. Disconnect the motor electrical plug from the blower motor 
assembly.
4. Remove the screws that secure the blower motor assembly 
to the in-line blower housing and set them aside.
5. Pull the spring clip to release the blower motor assembly. 
Remove the blower motor assembly from the housing and 
place it on a covered surface.
Installation of the In-line Blower System
NOTE: The blower motor housing can be mounted using 4 holes 
from either the outlet side or the inlet side of the blower.
Outlet Side:
Inlet Side:
1. Position the in-line blower motor housing in its mounting 
location and mark the 4 mounting hole locations.
WARNING
Excessive Weight Hazard
Use two or more people to move and install 
range hood.
Failure to do so can result in back or other injury.
A. Front cover
B. Blower mounting screws
C. Spring clip
D. Motor electrical plug
A. Mounting holes
A. Mounting holes
A
B C
D
A
A
A
A
A
A