Blodgett SN-5G Benutzerhandbuch

Seite von 20
12
4.0
 OPERATION INSTRUCTIONS
WARNING:  The steamer and its parts are hot.  Use care when operating, cleaning or
servicing the steamer.  The cooking compartment contains live steam.  Stay clear
when opening door.
Your steamer has been factory set when “ON” to maintain water temperature during the
READY phase at approximately 205º Fahrenheit (97º Celsius) just below water boiling
point.
CONTROLS
Ready Pilot Light
When lit, indicates steam chamber has reached 205º Fahrenheit (97º Celsius) and is
ready for the cooking cycle.
Cooking Pilot Light
When lit, indicates that a cooking cycle is in progress.
Timer
Set the cooking time (0 to 60 minutes) - steam cooking will begin when the door is
closed.  The cooking cycle will be interrupted if the door is open during the cooking
cycle; resume cooking by closing the door.
Main Power Switch
ON - The boiler will automatically fill and begin heating to the pre-set temperature.
OFF -  The boiler will drain.
DELIME - Closes the drain valve while CLR liquid is being poured into the generator
during the Delime procedure.
Ignition Light
When lit, indicates burners have been ignited and are heating the generator tank.
WARNING:  In the event of main burner ignition failure, a 5 minute purge
period must be observed prior to re-establishing ignition source.  If so
equipped, some units will automatically re-attempt ignition.