3    Operation 
3.7.3 
Maximum pump capacity 
The maximum delivery capacity setting allowed for the dispensing system (pump 
motor speed) can be adjusted on the speed controller.  
An error message is displayed whenever a higher speed is selected on the speed 
controller – see Section 4.3. 
Maximum speed / delivery capacity setup: 
•  With the dispensing station in ready state, push OK button three times - display 
indicates Range Max.. 
 
 
•  Use arrow keys to enter desired value. 
Arrow key assignment / setting range: 
left: -10; right: +10; up: +1; 
down: -1; setting range: 30 – 100 
• Push OK button to save the setting – display indicates "next menu item". Push 
ESC key to leave the operator menu – display indicates Operation
For recommended values see Section 8.4. 
3.7.4 Operating 
mode 
Two operating modes are available: Continuous mode or Timed mode 
Continuous mode:   Dispensing station delivers product as long as  meter-mix 
dispense gun is actuated. 
Timed mode:     Dispensing station delivers product during a pre-set time span 
after the meter-mix dispense gun has been actuated. (for dispense time setup see 
next menu). 
  The operating mode setting is indicated in the Operation display. 
Select operating mode: 
•  With the dispensing station in ready state, push OK button 4 times - display 
indicates Operating mode.. 
 
 
or 
 
•  Use arrow keys to enter desired value. 
Arrow key assignment: left: Continuous mode; right: Timed mode. 
•  Press ALT key to jump directly to the Dispense time display.  
• Push OK button to save the setting – display indicates "next menu item". Push 
ESC key to leave the operator menu – display indicates Operation
Range max.
75 %
OK/ESC
*
Cont.
A:B
2.00:1
Max.
70%
OK
Time
9.2 sec.
A:B
2.00:1
Max.
70%
OK