TO PROGRAM OPTIONAL FILL VALVE
1. Push the Program button and then the up button and display will show “SET #
OF HOURS TO FILL (1 OR 2 HRS).” Number of hours to fill pool may be
adjusted between 1 and 2 hours by pushing the Up button. 
2. To start filling the pool, push the Down button. This will turn on the fill valve.
Display will show the “FILL” icon. 
3. When the pool is filling, pushing the Up button will turn the fill valve off. 
TO PROGRAM KEYPAD LOCK FEATURE
1. Push Program, then push Spa twice.  The display will show ON or OFF, push Program to select.  ON means 
all keypads will function.  OFF means all keypads on all panels and remotes will be locked except for the
service panel.
2. Press Spa to exit.
3. To unlock, press Program.
THE FOLLOWING MESSAGES MAY APPEAR ON THE LCD SCREEN OF THE MASTER CONTROL PANEL:
WARNING: THE SYSTEM IS NOT MEANT TO BE SERVICED BY THE CONSUMER. 
RISK OF ELECTRIC SHOCK EXISTS INSIDE THE MASTER CONTROL PANEL.  CONTACT YOUR LOCAL SERVICE
PERSON FOR APPROPRIATE ACTION.
7
BASIC PROGRAMMING OF MASTER CONTROL PANEL (continued)
TROUBLESHOOTING
LCD 
MESSAGE
PROBLEM
WATER TEMPERATURE
HIGH LIMIT
WATER TEMPERATURE
SENSOR FAILURE
AIR TEMPERATURE
SENSOR FAILURE
FREEZE PROTECTION
ACTIVATED
WATER TEMPERATURE
GREAT THAN 110°
RECOMMENDED ACTION
This is displayed when the water in the pool/spa system reaches 
112 degrees.  SYSTEM WILL RESET ITSELF ONCE THE WATER
TEMPERATURE REACHES 110 DEGREES.  IF PROBLEM PERSISTS,
CONTACT YOUR SERVICE PERSON FOR APPROPRIATE ACTION.
CONTACT SERVICE PERSON FOR REVIEW AND POSSIBLE SENSOR
REPLACEMENT IF SENSOR IS FOUND TO BE DEFECTIVE.
CONTACT SERVICE PERSON FOR REVIEW AND POSSIBLE SENSOR
REPLACEMENT IF SENSOR IS FOUND TO BE DEFECTIVE.
NO ACTION REQUIRED.  Safety feature built into system to avoid damage to
equipment. Activated when water temperature reaches 35 degrees.  Pump will
run for 1/2 hour intervals while temperature is at or below 35 degrees.  This
feature is only active when valves are in the pool mode.
NO ACTION REQUIRED.  OH message will appear if the water in the pipes does
not cool to below 110° within 5 minutes.
OH
SN1
SN2
ICE
hot
Hayward Pool Products Worldwide Locations
Hayward Corporate Headquarters
Hayward Pool Products, Inc.
900 Fairmount Avenue
Elizabeth, NJ 07207, USA
Tel:  908 351 5400
Fax: 908 351 5675
Hayward Pool Products, Inc.
2875 Pomona Boulevard
Pomona, CA 91768, USA
Tel:  909 594 1600
Fax: 909 598 6905
Hayward Pool Products Canada, Inc.
2880 Plymouth Drive
Oakville, Ontario, CANADA, L6H 5R4
TEL: 905 829 2880
FAX: 905 829 3636
Hayward Pool Europe:
ZA de l’Observatoire
2, Avenue des Chaumes
78182 St. Quentin en Yvelines Cedex,
FRANCE
TEL:  33 1 39 30 91 00
FAX:  33 1 39 30 91 89
Hayward Iberica S.A.
Carretera Nacional III, KM 333, 7 Nave 2
E-46930 Quart De Poblet, Valencia,
SPAIN
TEL: 34 6 152 3454
FAX: 34 6 152 3357
Hayward/IMG
International Marketing Group
801 Corporate Center Drive, Suite 110
Pomona, CA 91768, USA
Tel:  909 620 4041
Fax: 909 620 1249
For further information or consumer technical support, please call 866-772-2100 
or visit our web site at www.haywardnet.com
OH