Hamilton Sundstrand Company Fuel Metering Valves XVG Benutzerhandbuch

Seite von 36
 
 
 
Register 
Number 
XVG/eXVG Parameter 
Name 
Write 
Access 
Corresponding Demand 
Type 
Pre-
Cal 
Default 
5670 5671 
IDM_POSTBL35 
W2
 
Counts: 2218.6250, 13.0mA Demand 
U32
 
567968 
5672 5673 
IDM_POSTBL36 
W2
 
Counts: 2389.2500, 14.0mA Demand 
U32
 
611648 
5674 5675 
IDM_POSTBL37 
W2
 
Counts: 2559.8750, 15.0mA Demand 
U32
 
655328 
5676 5677 
IDM_POSTBL38 
W2
 
Counts: 2730.5000, 16.0mA Demand 
U32
 
699008 
5678 5679 
IDM_POSTBL39 
W2
 
Counts: 2901.1250, 17.0mA Demand 
U32
 
742688 
5680 5681 
IDM_POSTBL40 
W2
 
Counts: 3071.7500, 18.0mA Demand 
U32
 
786368 
5682 5683 
IDM_POSTBL41 
W2
 
Counts: 3242.3750, 19.0mA Demand 
U32
 
830048 
5684 5685 
IDM_POSTBL42 
W2
 
Counts: 3413.0000, 20.0mA Demand 
U32
 
873728 
  
Table 17:  Position Interpolation Table Parameters 
 
 
9.1.3  Stroke Position Parameters 
 
For XVG/eXVG low measurement and flow control accuracy improvement, the CdA 
values are calculated based not only stroke position (using stroke- CdA interpolation 
table) but also on pressure ratio condition. 
The following Stroke Position Table lists default values of fifteen stroke positions that 
will be used in CdA values calculation.   Table values are (stroke value*2
24
). 
 
 
Register 
Number 
XVG/eXVG Parameter 
Name 
Write 
Access 
Corresponding Stroke 
Type 
Default 
Value 
5900 5901 
IDM_STROKETBL0 
W4 
0.005 
U32 
83886 
5902 5903 
IDM_STROKETBL1 
W4
 
0.01 U32
 
167772 
5904 5905 
IDM_STROKETBL2 
W4
 
0.015 U32
 
251658 
5906 5907 
IDM_STROKETBL3 
W4
 
0.03 U32
 
503316 
5908 5909 
IDM_STROKETBL4 
W4
 
0.045 U32
 
754975 
5910 5911 
IDM_STROKETBL5 
W4
 
0.0625 U32
 
1048576 
5912 5913 
IDM_STROKETBL6 
W4
 
0.078125 U32
 
1310720 
5914 5915 
IDM_STROKETBL7 
W4
 
0.09 U32
 
2097152 
5916 5917 
IDM_STROKETBL8 
W4
 
0.1 U32
 
2621440 
5918 5919 
IDM_STROKETBL9 
W4
 
0.125 U32
 
2936013 
5920 5921 
IDM_STROKETBL10 
W4
 
0.15625 U32
 
3355443 
5922 5923 
IDM_STROKETBL11 
W4
 
0.175 U32
 
3774874 
5924 5925 
IDM_STROKETBL12 
W4
 
0.2 U32
 
4194304 
5926 5927 
IDM_STROKETBL13 
W4
 
0.225 U32
 
4194472 
5928 5929 
IDM_STROKETBL14 
W4
 
0.25 U32
 
4194640 
Table 18:  Stroke Position Table Parameters 
 
 
 
9.1.4  Pressure Ratio Parameters 
 
These pressure ratio values are used in calculation of CdA values based on stroke and 
pressure ratio conditions.  Table values are (pressure ratio value*2
24
). 
 19