GSI Outdoors 100 SERIES DRYER PNEG-552 Benutzerhandbuch

Seite von 64
6. Dryer Start-Up
PNEG-552 100 Series Dryer
33
100 Series Continuous Flow Metering Roll Settings
Adjusting the Moisture Control
1. 5° on the moisture control will change the output moisture by about 1%. Example: With 100° set, 
the result is 16% corn but 17% corn is desired. Reduce the moisture control setpoint temperature 
by 5° to 95°. This should change the moisture out to about 17%. If you want the corn to come out 
dryer, raise the temperature on the moisture control setpoint.
2. Four (4) sensors are averaged together for sensing moisture control temperature, one (1) on each 
side of the dryer in the front, and one (1) on each side of the dryer in the back. They are located 
about 1/3 of the way up the grain column from the bottom, and in from the side about 4''.
3. Grain temperatures can be monitored by pressing the mode select button.
4. The moisture control should stay on HIGH about 50% to 90% of the time. There is a broad range 
that will work. It should switch from low to high and back again to maintain the desired moisture. A 
control that does not switch will not maintain an evenly dried grain moisture when the incoming wet 
grain moisture varies.
5. If the metering roll switches to LOW and stays there for long periods of time, both the High
and Low Speed Potentiometers should be slowed down 2% (20 points) and monitored for
further adjustment.
6. If the metering roll switches to HIGH and stays on HIGH more then 90% of the time, increase the 
speed on both Potentiometers 2% (20 points) and monitor for further adjustment.
7. When adjusting the METER ROLL SPEEDS it is better not to change the speed more than 20 points 
(2%) at a time.
8. Anytime a change is made, wait the approximate dry time for that moisture grain from the 
 before checking the grain moisture level and making another change if necessary. 
Initial 
Moisture (%)
Moisture 
Removed (pts.)
Full Heat
Approximate
 Dry Time (min.)
1 Speed
2 Speed 
Low
2 Speed 
High
17
2
16
625
317
875
18
3
21
476
270
775
19
4
26
385
241
675
20
5
31.5 317
213
575
21
6
37
270
196
476
22
7
41.5
241
185
385
23
8
47
213
172
317
24
9
51
196
161
270
25
10
54
185
150
241
26
11
58
172
140
213
27
12
62
161
132
196
28
13
66.5 150
123
185
29
14
71.5
140
116
172
30
15
76
132
110
161
31
16
81
123
104
150
32
17
86
116
100
140
33
18
91
110
096
132
34
19
96
104
087
123
35
20
100
100
082
116
These are approximate starting points.