Black Box 16 port Benutzerhandbuch

Seite von 263
Black Box Console Server user guide
168
line-service 
select from one of: cslogin, direct, silent, reverse, bidir, slip or ppp.
for remote access connections, see 
when you select ‘direct’, ‘silent’ or ‘reverse’, you must specify whether the 
line service is ‘raw’,‘telnet’or ‘ssh’; e.g. silent telnet.
when you select ‘direct’, ‘silent’ or ‘bidir’, you must enter the target host 
name; e.g. sophocles.
when you select ‘direct raw’, ‘silent raw’ or ‘bidir’, you must specify the 
TCP port assigned on the target host to listen for the incoming connection.
when you select ‘reverse raw’ ‘reverse ssh’or ‘bidir’, you must specify the 
TCP port assigned to the unit’s port (that is the Console Server TCP port 
number). TCP/IP hosts will use this TCP port to establish a connection with 
the unit.
phone-number
a number which the unit will dial on that line, when ‘dial’ is set to ‘out’. 
Enter the number without spaces. To change the phone number overwrite the 
previous entry.
modem-name
is the name of the attached modem; e.g. usrobotics28.8, or a name you wish 
to use, e.g. modem 1. Do not enter spaces in the name; use the underscore  
_ character; e.g. us_robotics_28.8. You can enter a total of nineteen 
alphanumeric characters (including spaces).
i-timer value
enter a period in seconds for which the idle timer will run. Use this timer to 
close a connection because of inactivity. When the idle timer expires, if there 
has been no exchange of data, the unit will end the connection. The default 
value is 0 (zero), meaning that the idle timer will not expire (the connection is 
open permanently).
This idle timer will be overridden by the idle timer which you can configure 
for a user; i.e. the user idle timer takes precedence.
s-timer value
enter a period in seconds for which the session timer will run. Use this timer 
to forcibly close the session (connection). When the session timer expires the 
unit will end the connection. The default value is 0 (zero), meaning that the 
session timer will not expire (the session is open permanently, or until you 
kill the line or you/the user log(s) out).
This session timer will be overridden by the session timer which you can 
configure for a user; i.e. the user session timer takes precedence.