GE General Electric Oxygen Equipment PT878 Benutzerhandbuch

Seite von 297
Chapter 5. Displaying and Configuring Data
104
Transport® Model PT878 Portable Liquid Flowmeter User’s Manual
5.6.1 Transferring a File to a PC
To upload a log, meter, bitmap or site file to a PC:
1.
Check that the Communications option on the PT878 (see page 123) 
has been set to the IrDA protocol, and that the IR beam on the PT878 
has clear access to the IR sensor connected to the PC port.
Note:
For Windows NT4.0, check that the QuickBeam software (available 
through the path C:\Program Files\QuickBeam Suite) is running.
2.
Highlight the desired site in the left window of the Drive Manager.
3.
Press 
[MENU]
, scroll to the Transfer option, and press 
[ENTER]
The screen shows a message indicating that the PT878 is searching for an 
infrared device. (If the scanner spots no device, a window appears with this 
message, and asks if you want to try again.) If it finds a device, it sends 
another message indicating that it is uploading the site. (The meter also 
displays a message if the upload fails.) When the upload is complete, the 
meter returns to the Drive Manager. The PC holds the transferred file in the 
C:\IR_Inbox folder (C:\My Received Files for Windows 98, or Desktop for 
Windows 2000), as shown in Figure 68 below. You can open the file on the 
PC using any text editor.
Figure 68: IR_Inbox Folder - Transferred File