GE General Electric Oxygen Equipment PT878 Benutzerhandbuch

Seite von 297
Chapter 10. Specifications
Transport® Model PT878 Portable Liquid Flowmeter User’s Manual
213
Chapter 10.Specifications
This section contains specifications for the following:
Overall
Electrical
Transducer
Fluid Types
Pipe Size and Materials
Available Options
10.1 Overall
10.1.1 Hardware Configuration
Channel Options: Single channel
Mode Options: Transit-time
10.1.2 Size/Weight
Size without boot:  238 
× 138 × 38 mm 
                                 (9.4 
× 5.5 × 1.5 inches)
Weight with boot:    1.36 kg (3 lb)
10.1.3 Enclosure
Submersible, IP67
10.1.4 Flow Accuracy (Velocity, % of reading):
Clamp-on Transducers: Pipe Diameter > 150 mm (6 in.)
±1% to 2% of reading typical
Pipe Diameter 
 150 mm (6 in.)
±2 to 5% of reading typical