7 Troubleshooting 
 
If you are unable to verify capture of transaction text, do the following: 
 
1.  Check that each device is properly powered. 
2.  Check that the ECR to Camera address is correctly programmed SW1
3.  Check that all cables and cable connections are correct 
4.  If data is being displayed but is not intelligible, the likelihood is that the 
baud rate is different than the default value for the selected register.  
Check with the baud rate settings for the Receipt Printer on your POS 
system. 
To change the Baud Rate, the available settings are controlled via the 
dipswitch settings on SW2 (dipswitches 2-4).
 
 
Legend: 
Up (Off) = U 
 
Down (On) = D 
SW2 
Switch Setting 
Baud Rate 
Port 2 
1200 
2400 
4800 
9600 
14.4k 
19.2k 
38.4k 
 
5.  If the DVMRe is not receiving data at all, you can use a built-in 
demonstration text message to verify that the PB3 is passing data to the 
DVMRe (see Section 6.2 for demo mode).   
 
a.  Remember to return the dipswitches to the normal mode 
(Demo mode off). 
6.  If you are still unable to get the Interface to work, please contact Kalatel 
Technical Support.