GE MAC-VME/VXI Datenbogen
![GE](https://files.manualsbrain.com/attachments/ab9edb4caba5619c2fde3c8024ebd3386de893ab/common/fit/150/50/5e42700264754ddc6c8abde125a62fae9215a8ad130cb92d4b61e1d54d06/brand_logo.jpeg)
04.12 GFA-1865
©2012 GE Intelligent Platforms, Inc. All rights reserved.
All other brands or names are property of their respective holders.
Specifications are subject to change without notice.
GE Intelligent Platforms Contact Information
Americas:
1 877 429 1553 Global regional phone numbers are listed by location on our web site at
defense.ge-ip.com/avionics-contacts
defense.ge-ip.com/avionics
About GE Intelligent Platforms
GE Intelligent Platforms is a division of GE that offers software, control systems, services, and expertise
in automation and embedded computing. We offer a unique foundation of agile and reliable technology
providing customers a sustainable competitive advantage in the industries they serve, including energy,
water, consumer packaged goods, oil and gas, government and defense, and telecommunications. GE
Intelligent Platforms is headquartered in Charlottesville, VA. For more information, visit www.ge-ip.com.
in automation and embedded computing. We offer a unique foundation of agile and reliable technology
providing customers a sustainable competitive advantage in the industries they serve, including energy,
water, consumer packaged goods, oil and gas, government and defense, and telecommunications. GE
Intelligent Platforms is headquartered in Charlottesville, VA. For more information, visit www.ge-ip.com.
MAC-VME – VME/VXIbus MAC (Modular Avionics Controller)
Specifications
ARINC 429 Receive Channels
• Number of channels: 2 to 64 (32 max per module)
• Data rates: 12.5 KHz, 100 KHz or 3 KHz to 150 KHz
• Number of channels: 2 to 64 (32 max per module)
• Data rates: 12.5 KHz, 100 KHz or 3 KHz to 150 KHz
programmable
• Standard Input levels: ± 6.5 to ±13 VDC (A to B)
• Filtering: channel, label and/or SDI
• Parity: odd, even or none
• Error reporting: parity
• Buffer up to 2,048 labels per channel
• Filtering: channel, label and/or SDI
• Parity: odd, even or none
• Error reporting: parity
• Buffer up to 2,048 labels per channel
ARINC 429 Transmit Channels
• Number of channels: 2 to 32 (16 max per module)
• Data rates: 12.5 KHz, 100 KHz or 3 KHz to 150 KHz
• Number of channels: 2 to 32 (16 max per module)
• Data rates: 12.5 KHz, 100 KHz or 3 KHz to 150 KHz
programmable
• Automatic slew rate adjustment
• Standard Output level: ±10 VDC (A to B)
• Parity: odd, even or none
• Error injection: parity, gap, high or low bit count
• Buffer up to 8192 labels per channel
• Standard Output level: ±10 VDC (A to B)
• Parity: odd, even or none
• Error injection: parity, gap, high or low bit count
• Buffer up to 8192 labels per channel
ARINC 717/573 Channels
• Number of channels: up to 4 (1 transmit and 1 receive
• Number of channels: up to 4 (1 transmit and 1 receive
per module)
• Selectable encoding: Harvard Bi-Phase or BiPolar
Return-to-Zero Operation
• Data rate / frame size: 384 bps/ 32 words to 48 Kbps/
4K words
• Buffer up to 2048 words per receive channel
• Buffer up to 8192 words per transmit channel
• Buffer up to 8192 words per transmit channel
ARINC 708 Channels
• Number of channels: up to 4 (2 per module)
• Selectable: each channel either Rx or Tx
• Data rate: 1 MHz
• Bits per frame: 64 bits control, 1536 bits data (1600
• Number of channels: up to 4 (2 per module)
• Selectable: each channel either Rx or Tx
• Data rate: 1 MHz
• Bits per frame: 64 bits control, 1536 bits data (1600
total)
• Scheduled sweep transmit buffers: up to 2600 frames
per channel
• Received frame buffers: 2600 frames
• Error injection: short/long frames, sync
• Error injection: short/long frames, sync
Operating Temperature
• 0° to 60°C
• 0° to 60°C
Physical VME (6U board) / VXI (C-size)
• Height: 9.2” (23.34 cm)
• Depth: [VME] 6.3” (16.0 cm) / [VXI] 13.4” (33.99 cm)
• Front panel width: 0.8” (1.98 cm)
• Height: 9.2” (23.34 cm)
• Depth: [VME] 6.3” (16.0 cm) / [VXI] 13.4” (33.99 cm)
• Front panel width: 0.8” (1.98 cm)
VME/VXI Interface
• Optional P-2 Rear I/O for single PMC Slot
• A24, A32 addressing
• D16, D32 data transfer
• VME/VXI slave
• Optional P-2 Rear I/O for single PMC Slot
• A24, A32 addressing
• D16, D32 data transfer
• VME/VXI slave
Power (typical)
• +5 VDC: TBD
• +12 VDC: TBD
• -12 VDC: TBD
• +5 VDC: TBD
• +12 VDC: TBD
• -12 VDC: TBD
Warranty
2 year limited hardware warranty
2 year limited hardware warranty
Ordering Information
MAC-A13J-A13JM
Modular 6U VME card with 26 RX, 26 TX ARINC 429 channels & 2 RX, 2 TX DUAL-MODE (either
HBP or BPRZ) ARINC 717 channels.
HBP or BPRZ) ARINC 717 channels.
MAC-A13JM
Modular 6U VME card with 13 RX, 13 TX ARINC 429 channels & 1 RX, 1 TX DUAL-MODE (either
HBP or BPRZ) ARINC 717 channels.
HBP or BPRZ) ARINC 717 channels.
MAC-A16-A16M
Modular, 6U VME card with 32 RX and 32 TX ARINC 429 channels.
MAC-A16-A16X
Modular, 6U VXI card with 32 RX and 32 TX ARINC 429 channels.
MAC-A16-D232M
Modular, 6U VME card with 16 RX and 16 TX ARINC 429 channels; 16 PORTS RS-232
MAC-A16M
Modular, 6U VME card with 16 RX and 16 TX ARINC 429 channels.
MAC-A2J-A2JX
Modular, C-SIZE VXI card with 4 RX, 4 TX channels of ARINC 429 and 2 RX, 2 TX channels of
dual-mode ARINC 717/573
dual-mode ARINC 717/573
MAC-A4-C422M
Modular, C-SIZE VME card with 4 RX and 4 TX ARINC 429 channels & 8 PORTS RS422
MAC-A8-C44X
Modular, C-SIZE VXI card with 8 RX and 8 TX ARINC 429 channels, 4 PORTS RS-232 and 4 ports
of RS422.
of RS422.
MAC-A8M
Modular, 6U VME card with 8 RX and 8 TX ARINC 429 channels.
MAC-A8X
Modular, C-SIZE VXI card with 8 RX and 8 TX ARINC 429 channels
MAC-AIC-A3216Q1
Modular, 6U VME card with AIC adaptor, 32 RX and 16 TX ARINC 429 channels,
PMC’S on VME carrier
PMC’S on VME carrier
MAC-H2X
Modular, C-SIZE VXI card with 1 RX, 1 TX 708 channel
MAC-W16-W16M
Modular, 6U VME card with 32 RX AND 32 TX ARINC 429 channels, WITH IRIG
MAC-W4M
Modular, 6U VME card with 4 Rx, 4 Tx ARINC 429 channels, with IRIG-B
LABView Support
CEI-LV provides ready-to-use, ARINC 429 LabVIEW
application examples in VI source that can be quickly
integrated into your custom LabVIEW application.
Rapidly build applications to simulate or monitor
multiple ARINC 429 channels in real-time, filter and time-
tag data and create custom displays. VI’s are provided
for initialization, channel configuration, error handling,
transmitting or receiving multiple messages, and engi-
neering unit conversion.
application examples in VI source that can be quickly
integrated into your custom LabVIEW application.
Rapidly build applications to simulate or monitor
multiple ARINC 429 channels in real-time, filter and time-
tag data and create custom displays. VI’s are provided
for initialization, channel configuration, error handling,
transmitting or receiving multiple messages, and engi-
neering unit conversion.
Configuration Assistance
The inherent flexibility of MAC family products for VME
and VXI platforms offers a large number of possible
configurations, and we are adding new options. Our
knowledgeable sales team will help you define your
customized solution.
and VXI platforms offers a large number of possible
configurations, and we are adding new options. Our
knowledgeable sales team will help you define your
customized solution.