3.3.1 
Connecting Twisted Pair (RJ-45, Unshielded or Shielded)  
 
The following procedure describes how to connect a 10BASE-T twisted pair 
segment to the RJ-45 port on the RPM -TP.  The procedure is the same for both unshielded 
and shielded twisted pair segments. 
 
1.    Using standard 10BASE-T media, insert either end of the cable with an RJ-45 plug 
into the RJ-45 connector of the RPM-TP. Note that, even though the RPM -TP connector 
is shielded, either unshielded or shielded 10BASE-T cables and wiring may be used. 
2.   Connect the other end of the cable to the corresponding device. 
3. 
Use the LINK LED to ensure proper connectivity by noting that the LED will be 
illuminated when the unit is powered and proper connection is established.  If the LINK 
LED is not illuminated, change the setting of the up-link switch.  If this does not help, 
ensure that the cable is connected properly and  is not defective.  
 
 
The Magnum RPM-TP is equipped with a up -link slide switch to accommodate 
repeater-to-repeater connections without special cross-over connectors.   
NOTE:  When installing a Magnum 200XX-TT Workgroup Bridge, the up-link switches of 
both connectors should have the same setting ( both left or both right).  When installing a 
Magnum 200X  with only one twisted pair port, you will normally set the up -link switch to 
the DOWN (or RIGHT) position, however  this is dependent on your network 
configuration (see step 3 above). 
 
3.3.2 
Connecting ThinNet 10BASE2  (BNC)