MFJ-1278B MULTI-MODE                                     BASIC OPERATION 
As indicated in the preceding paragraph, the usual terminal/radio/modem parms are available. 
 
As in Packet, Pactor also contains  COMMAND and  CONVERSE modes.  Please note that 
switching between them is modeled on the "NEWMODE ON" procedures in packet.  The MFJ-
1278B is in COMMAND mode, if the p_cmd: prompt is on the computer screen.  To switch 
to CONVERSE mode from COMMAND mode the K key followed by an <ENTER> is issued 
by the user.  The  CMDCHR character switches the MFJ-1278B from  CONVERSE mode 
back to  COMMAND mode.  The  CMDCHR character is defined as  CTRL-C.  Once 
connected, the link acts much like AMTOR. 
 
The station originating the connection is the master and he remains in transmit mode until he or 
the slave initiates a changeover.  Either station may reverse the direction of the link by issuing 
a control-Y changeover (^Y) in converse mode. 
PACTOR FEATURE DEFINITIONS 
DIGITAL MEMORY ARQ 
The MFJ-1278B's Pactor incorporates a  Digital Memory ARQ mode.   Digital Memory 
ARQ
 enables reconstruction of a good packet from a bad packet.  A bad packet is one 
repeatedly received with on or more bit errors.  Digital Memory ARQ accumulates the bit 
value, 1 or 0 derived from the RF port during successive reception of the same error-laden 
packet.  These bit accumulations are sent to the receiver shift register.  Thus a good packet is 
reconstructed from 2 or more "bad" packets. 
 
The  MAXSUM parameter controls the number of accumulations performed for each bit.  
Larger MAXSUM values increase the effectiveness of the Digital Memory ARQ scheme, but 
only to a certain point.  The reception of an almost perfect packet will be inadequate to 
overcome the accumulated noise, if  MAXSUM is too large.  Also the presence of excessive 
QRM, QRN, or QSB effects the reception of good packets.  On the other hand, if MAXSUM is 
too small the accumulation of samples will be too few to correct for moderate error rates.  The 
factory setting for MAXSUM represents a good compromise--feel free to play with it. 
FEC UNPROTO 
Unproto: "FEC/UNPROTO"  packets are transmitted UREPEATS+1 times.  Selecting larger 
values of UREPEATS reduces throughput, but enhances reliability.  To transmit in UNPROTO 
mode, issue the appropriate unproto command and type away.  When done, break out to 
"p_cmd:" mode and type 'D' or 'DD' to terminate transmission.   
MONITORING 
Monitoring unproto:  If  MONITOR is  ON the MFJ-1278B is always in  listen mode, 
except when connected to another station.  There are other situations occur that prevent the