Whirlpool WFG510S0AW Anleitung Für Quick Setup

Seite von 20
9
3. Use a 
¹⁵⁄₁₆" combination wrench and channel lock pliers to 
attach the flexible connector to the adapters. Check that 
connector is not kinked.   
Complete Connection
1. Check that the gas pressure regulator shutoff valve is in the 
“on” position.
2. Open the manual shutoff valve in the gas supply line. The valve 
is open when the handle is parallel to the gas pipe.
3. Test all connections by brushing on an approved noncorrosive 
leak-detection solution. If bubbles appear, a leak is indicated. 
Correct any leak found.
4. Remove cooktop burner caps and grates from parts package. 
Burner caps should be level when properly positioned. If burner 
caps are not properly positioned, surface burners will not light. 
Place burner grates over burners and caps.
5. Plug into a grounded 3 prong outlet.
6. Slide range into final location, making sure the rear leveling leg 
slides into the slot of the anti-tip bracket.
Verify Anti-Tip Bracket Is Installed and 
Engaged
On Ranges with a Storage Drawer:
1. Remove the storage drawer. See “Storage Drawer” section.
2. Use a flashlight to look underneath the bottom of the range.
3. Visually check that the rear range foot is inserted into the slot of 
the anti-tip bracket.
On Ranges with a Warming Drawer or Premium Storage 
Drawer:
1. Place the outside of your foot against the bottom front of the 
warming drawer or premium storage drawer, and grasp the 
lower right or left side of the control panel as shown.
NOTE: If your countertop is mounted with a backsplash, it may 
be necessary to grasp the range higher than is shown in the 
illustration.
2. Slowly attempt to tilt the range forward. 
If you encounter immediate resistance, the range foot is 
engaged in the anti-tip bracket.
3. If the rear of the range lifts more than ½" (1.3 cm) off the floor 
without resistance, stop tilting the range and lower it gently 
back to the floor. The range foot is not engaged in the anti-tip 
bracket.
A. Gas pressure regulator
B. Use pipe-joint compound.
C. Adapter (must have ½" male 
pipe thread)
D. Flexible connector
E. Manual gas shutoff valve
F. ½" or ¾" gas pipe
G. Use pipe-joint compound.
H. Adapter
A. Gas pressure regulator shutoff valve
shown in the “on” position
A. Closed valve
B. Open valve
A. Burner base
B. Burner cap
C. Burner grate
A
B
C
D
E
F
G
H
A
A
C
A
B
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
WARNING