Wolf SO30-2F/S Merkblatt
E Series Built-In Single Oven
Installation Notes
Wolf E Series built-in ovens may be used in
a standard installation, where the face trim
overlaps stiles and rails, or in a flush inset
installation with the front of the oven flush
with surrounding cabinetry.
a standard installation, where the face trim
overlaps stiles and rails, or in a flush inset
installation with the front of the oven flush
with surrounding cabinetry.
Complete installation specifications can be
found on our website, wolfappliance.com.
found on our website, wolfappliance.com.
Unit dimensions may vary by ±
1
/
8
".
27
3
/
16
"
(691)
OPENING
HEIGHT
28
1
/
2
"
(724)
OPENING WIDTH
5"
(127)
4"
(102)
24"
min (610)
OPENING DEPTH
E
E
E
E
33"
(838)
RECOMMENDED CABINET WIDTH
30"
min (762)
ELECTRICAL LOCATION
WITHIN OPENING
APPLIES ONLY TO
CABINETS DEEPER
THAN 24" (610)
WITHIN OPENING
APPLIES ONLY TO
CABINETS DEEPER
THAN 24" (610)
Specifications
Overall Width
29
7
/
8
"
Overall Height
27
7
/
8
"
Overall Depth
23
3
/
4
"
Oven Door Clearance
22"
Oven Interior Capacity
4.5 cu ft
Oven Interior Dimensions
25" W x 16
1
/
2
" H x 19" D
Recommended Cabinet Width Standard 30"
Flush Inset 33"
Minimum Cabinet Depth
Standard 24"
Flush Inset 25"
Minimum Base Support
250 lbs
Opening Width
28
1
/
2
"
Min Inset Width
30
3
/
8
"
Opening Height
27
3
/
16
"
Min Inset Height
28
1
/
2
"
Electrical Requirements
240/208 V AC
60 Hz, 30 amp circuit
Electrical Rating
5.1 kW at 240 V
3.8 kW at 208 V
3.8 kW at 208 V
Shipping Weight
273 lbs
Installation
Specifications
Specifications
Standard Installation
Overall Dimensions
IMPORTANT NOTE: Unless you are using cabinets
deeper than 24" (610) for a standard installation or
25" (635) for a flush inset installation, it is recom-
mended that the electrical supply be placed in an
adjacent cabinet within reach of the conduit.
Choose the location shown in the illustrations that
best suits your installation.
deeper than 24" (610) for a standard installation or
25" (635) for a flush inset installation, it is recom-
mended that the electrical supply be placed in an
adjacent cabinet within reach of the conduit.
Choose the location shown in the illustrations that
best suits your installation.
23
3
/
4
"
(603)
BEHIND FRAME
27
7
/
8
"
(708)
28
1
/
4
"
(718)
29
7
/
8
"
(759)
23
3
/
4
"
(603)
INSTALLER
SUPPLIED CABLE
CHANNEL
OPEN OVEN DOOR
TOP VIEW
22"
(559)
1
1
/
4
"
(32)
1"
(25)
1
7
/
8
"
(48)
1
7
/
8
"
(48)
RIGHT SIDE VIEW
27
1
/
16
"
(687)
29
7
/
8
"
(759)
2
5
/
8
"
(67)
27
3
/
16
"
(691)
OPENING
HEIGHT
28
1
/
2
"
min
(724)
FLUSH
INSET
HEIGHT
30
3
/
8
"
min
(772)
FLUSH INSET WIDTH
28
1
/
2
"
(724)
OPENING WIDTH
5"
(127)
4"
(102)
E
E
E
E
36"
(914)
RECOMMENDED CABINET WIDTH
33"
min (838)
24"
min
(610)
OPENING
DEPTH
1"
(25)
25"
min
(635)
FLUSH
INSET
DEPTH
7
/
16
"
(11)
7
/
8
"
(22)
ELECTRICAL LOCATION
WITHIN OPENING
APPLIES ONLY TO
CABINETS DEEPER
THAN 25" (635)
WITHIN OPENING
APPLIES ONLY TO
CABINETS DEEPER
THAN 25" (635)
SIDE VIEW
TOP VIEW
Flush Inset
Installation
Installation
Dimensions in
parentheses are in
millimeters unless
otherwise specified.
parentheses are in
millimeters unless
otherwise specified.