Whirlpool Range PGR4410CDW Datenbogen

Seite von 2
36"
Height at full leg adjustment:
Side clearance 
from cooktop to 
18" above the 
cooktop is 3" on 
each side (see 
solid arera)
30" Min.
18"
Wall View
(not to scale)
Range
Upper cabinets 
can only be 13" 
deep maximum.
Over range 
cabinet is NOT 
recommended.
36"
Countertop
height
30"
30" Minimum 
cutout width 
Height of cooking surface: 35 7/8"
Height overall:
Case width:
Door swing:
Depth NOT including handle:
Height at 0" leg adjustment:
(not to scale)
Door open
Locate electrical 
supply outlet (flush 
with wall) within 
hashed area. Area is 
13" W X 9" H. 
located 9 3/8" above 
floor and 1 1/2" from 
right wall.
Wall View
 (not to scale)
11"
1"
28"
2 1/4"
Locate gas line
within shadded
area
Gas Location
Electric 
Location
35 1/2"
45 1/4"
29 7/8"
20 1/2"
45 1/4"
35 7/8"
29 7/8"
20 1/2"
26 1/8"
26 1/8"
• Units depth including door handle is 28 1/8".
• Can be installed with the back against (0") a vertical
combustible wall, and the sides below the cooktop
surface against (0") combustible base cabinets.
• Electrical requirements: 120 VAC,60Hz. 15 amp
grounded circuit protection is required.
• Gas requirements: Gas supply line should be 3/4".
Install a manual shutoff valve in an accessible location
in the gas line external to this appliance for the purpose
of turning on or shutting off gas to the appliance.  The
appliance is shipped from the factory equipped for use
with natural gas and can be converted to LP gas in the
field .  The maximum gas supply pressure for both LP
and natural gas is 14" WC.  Minimum Pressure for
Natural gas is 5" WC.  Minimum Pressure for LP gas is
11" WC.
• Proper operation requires use of range hood.
• Cabinetry over cooktop : 30" minimum clearance
between the top of the cooking surface and the bottom
of an unprotected wood or metal cabinet.  24" minimum
when bottom of wood or metal cabinet is protected by
not less than 1/4" flame retardant millboard covered
with not less than no. 28 MSG sheet steel, 0.015"
stainless steel, 0.024" aluminum or copper.
             See page 2 for additional information
www.dexpress.com  
DIMENSION EXPRESS  
Fax on Demand (775) 833-3600
•                             Dimensions (Actual Size)                            •
• NEVER reuse Data Sheets.  Data Sheets are subject to change without                          • Call Dimension Express if you have any questions at (775) 833-3633 •
notice.  Dimension Express is a FREE service bureau and is updated daily,                     • Always refer to a current Code at a Glance or manufacturer directory •
it makes far more sense to spend the time necessary to request new Data                    • Data Sheet codes change on the first of odd numbered months at 12:01am •
Sheets for each project, as opposed to the problems, time, costs, and risks
associated with reusing old Data Sheets.
Free Standing Gas Ranges:
PGR4410CDW and PGR4410CDQ
•                           Product Model Number (s):                            •
Subject to change without notice.  This system is designed to
be updated daily if necessary.  Dimension Express is not
responsible for use of superseded, voided, or outdated data
sheets.  Because of the difficulty or impracticability of deter-
mining actual damages, liability of Dimension Express shall
not exceed $50.00.
Copyright ©  Dimension Express, 2002.