World Marketing of America DFA-45 Merkblatt

Seite von 2
PART NO.
KEY NO.
DESCRIPTION
DFA45
DFA65/65T
DFA120/120T DFA170T/170C       DFA210T/210C
1
Fuel Tank Assembly
Pre 04”
21-1001
21-1001
21-1002
21-1003
21-1003
1
Fuel Tank Assembly 04-05
21-1401
21-1401
21-1402
21-1403
21-1403
1.1
Drain Plug
N/A
N/A
21-4401
21-4401
21-4401
2
Fuel Gauge
21-1004
21-1004
21-1005
21-1005
21-1005
3
Fuel Filter Assembly
21-1006
21-1006
21-1007
21-1007
21-1007
4
Fuel Cap
21-1008
21-1008
21-1008
21-1008
21-1008
5
Power Cord
21-1009
21-1009
21-1009
21-1009
21-2101
6
Power Switch
21-1010
21-1010
21-1010
21-1010
21-1010
7
Display P.C.B. Assembly
21-1011
21-1011
21-1011
21-1012
21-1012
8
Thermostat Control Knob
-----
-----
21-1013
21-1013
21-1013
9
Lower Shell
Reference
Reference
Reference
Reference Reference
10
Air Line
21-1017
21-1017
21-1018
21-1069
21-2108
11
Temperature Limit Control
21-1019
21-1019
21-1020
21-1020
21-2109
12
Combustion Chamber 03
21-1021
21-1021
21-1022
21-1023
21-2110
13
Photocell Holder
Reference
Reference
Reference
Reference Reference
14
Fuel Line
21-1024
21-1024
21-1025
21-1025
21-2111
15
Photocell FA1007
FA1007
FA1007
FA1007
FA1023BK
16
Burner Head Assembly
Reference
Reference
Reference
Reference Reference
16-1
Nozzle Kit
FA1001
FA1002
FA1003
FA1004
FA1011BK
16-2
Nozzle Seal Washer
21-1027
21-1027
21-1027
21-1027
21-1027
16-3
Nozzle Seal Spring
21-1028
21-1028
21-1028
21-1028
21-1028
16-4
Burner Head
21-1029
21-1029
21-1030
21-1031
21-1031
16-5
Spark Plug
FA1008
FA1008
FA1009
FA1009
FA1021BK
17
Motor and Pump Assembly
Reference
Reference
Reference
Reference Reference
17-1
Motor
21-1035
21-1035
21-1036
21-1037
21-2119
17-2
Pump Body
21-1038
21-1038
21-1038
21-1038
21-2120
17-3
Rotor Kit
FA1000
FA1000
FA1000
FA1000
FA1022BK
Rotor Only
21-2125
PLEASE READ OWNER’S MANUAL BEFORE PERFORMING 
ANY MAINTENANCE OR SERVICE
DuraHeat
®
Forced Air
Parts & Service Guide
FFOORR TTEECCHHN
NIICCAALL 
AASSSSIISSTTAAN
NCCEE CCOON
NTTAACCTT UUSS AATT::
Tech Assistance:  
814-643-2299
Ordering: 
800-233-3202
Fax:
800-421-1357
Email: 
tteecchhssvvcc@
@w
woorrllddm
mkktt--
iinngg..ccoom
m
or visit our website at: 
DuraHeat
®
Forced Air Heater
Troubleshooting Guide
Air Pressure Problems
Always use an air pressure gauge to check or set air pressures.
DFA-45
2.8 PSI
DFA-170T,170C
6.5 PSI
DFA-65
3.5 PSI
DFA-210T,210C
8.5 PSI
DFA-120,120T
4.5 PSI
If the pressure is TOO LOW turn the adjustment screw clockwise. This will increase the flame. 
If the pressure is TOO HIGH turn the adjustment screw counter-clockwise to reduce the flame.
Note: If the heater burns OK with the Upper Shell off, but turns off when the cover is installed, the
pressure is too low.
If you can't achieve the proper pressure setting - try pulling the air line off the pump body and block
air line fitting tight with finger then remove adjustment screw and  plug the hole tight with another fin-
ger.  This should peg pressure gauge. If it does not, the problem is inside the pump body.
Check for:  Cracked plastic cover
Cracked pump body
Cracked rotor
Loose pump body screws 
Rubber seal on filter seated properly
Sometimes it's hard to see the air leak.  A solution of 50/50 soap and water can be applied to the
pump to find the leak. 
CAUTION!  BE CAREFUL NOT TO APPLY THIS SOLUTION TO ANY ELECTRICAL PARTS AS
IT WILL DAMAGE THE COMPONENTS AND CREATE A SHOCK HAZARD.
If pressure gauge does peg - try removing the air line from the nozzle end and replace it at pump
body end.  Then plug air line and adjustment screw end.  If it does not peg the gauge, then the
problem lies with the Air Line.  The air line may be cracked, cut, torn, split, rotted, etc.  Replace the
Air Line to correct the problem.
OWNER’S MANUAL NOTE:  (WARNING)  Always review the owner’s manual completely before
operating or attempting to service or repair any appliance.  Failure to follow all instructions provided
in the owner’s manual may result in property damage, personal injury, or death.
7/07
Pt. No. FAPARTS