White Rodgers 36h Benutzerhandbuch

Seite von 24
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY 
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE 
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
The
 36H series gas valve has redundant and main 
solenoid valves that control gas flow to the main 
burners, a pressure regulator to maintain a constant 
outlet pressure, and a two position on/off switch for 
electrical shutoff. The valves are shipped from the fac-
tory set for natural gas non-piloted applications. 
See instructions in this document for modifications 
required if the valve is to be installed on an LP gas 
and/or piloted gas application.
36H SERIES
Universal Replacement Electronic Ignition Gas Valve
INSTALLATION INSTRUCTIONS
CONTENTS
Description  ..................................................... 
1
Specifications  ................................................. 
1
Precautions  ..................................................... 
3
Installation ...................................................... 
4
 
System Wiring
Adjustment  ..................................................... 
7
 
Pressure Regulator Adjustment
Lighting Instructions ........................................
 8
Contents French  ............................................. 
9
Contents Spanish  .......................................... 
17
T
ype of Gas: ......................   Natural Gas
Ambient Temperature:  ....  
-40° to 175°F
Pressure Rating: ...............  
14” W.C. (1⁄2 PSI) max.
Voltage: ............................  
24 VAC
Frequency: .......................  
50/60 Hz
Current: ............................   Single Stage - 
.410A
                                                            Two-Stage - 
.540A
Model 
No.
No. of 
Stages
Open
Characteristics
Proven/ 
Intermittent 
Pilot
HSI DSI
36H32
1
Fast
Yes
Yes Yes
36H33
1
Slow
Yes
Yes Yes
36H64
2
Fast
Yes
Yes Yes
36H65
2
Slow
Yes
Yes Yes
Pressure Regulator Adjustment Range ( in W.C.)
Single 
Stage
Two Stage
Low
High
Min Diff.
Low to High
Natural Gas
2.5 - 5.0
1.0 - 3.5
2.5 - 5.0
1.5
LP Gas
5.0 - 12.0
4.0 - 9.5
8.0 - 12.0
2.5
PIPE SIZES/CAPACITIES
Pipe Sizes 
Available (inches)
Capacity (BTU/hr) at 
1” W.C.
pressure drop across valve
AGA Std. Nat. Gas
(
1,000 btu/ cu. ft.)
LP. Gas 
(
2,500 btu/cu. ft.)
3/4” x 3/4” NPT 
300,000
486,000
1/2” x 3/4” NPT 
260,000
421,000
 
 
SPECIFICATIONS
 
 
DESCRIPTION
www.white-rodgers.com
www.emersonclimate.com
PART NO. 
37-7336A
1219