DOWN-FLOW INSTALLATION 
All P*DHX furnace models have been 
assembled for installation in the down-
flow position. Maintain all clearances to 
combustibles as outlined in Table 1. 
P*DHX models have available sub-bases 
for installations on combustible floors. 
The sub-bases provide a means of effec-
tively mating the supply air plenum with 
the furnace, and providing the necessary 
one-inch clearance to combustibles 
around the supply air plenum. 
HORIZONTAL INSTALLATION 
P*DHX furnaces models may be in-
stalled in either of the horizontal posi-
tions; warm air discharging left or warm 
air-discharging right by following these 
steps: 
1.  Rotate the furnace 90° to the de-
sired position. 
2.  Remove the three nut and washer 
sets fastening the oil burner assem-
bly to the furnace. Rotate the oil 
burner assembly to be in the normal 
upright position. 
3.  Re-align the oil burner assembly to 
the combustion chamber (fire-pot), 
and then secure into place with the 
three nut and washer sets. 
IMPORTANT
: Model P3DHX12F08001 
has an auxiliary limit control that must be 
in the upper position. Be sure that the 
auxiliary limit control is above the oil 
burner assembly. 
NON-SUSPENDED INSTALLATION 
Maintain clearances to combustibles as 
outlined in Table 1. Installation on a 
combustible floor requires a clearance of 
1 inch. This can be done by using a non-
combustible material such as one inch 
thick channel iron or similar material. The 
furnace must be supported in such a way 
as to not allow twisting or sagging of the 
cabinet. Suggestion; as a measure to 
prevent fuel oil from accumulating in 
locations other than the fire pot, as could 
be the case in the event of nozzle drip, 
install the furnace with an approximate 2 
degree slope from the oil burner casing 
towards the fire pot. Use shims made of 
noncombustible material. 
Table 1: Clearance to Combustibles 
 
Furnace P2LBX  P3DHX12F08001 
P2DHX16F12001 
Location 
Upflow  Downflow Horizontal Downflow Horizontal 
Top 
3 in. 
0 in. 
6 in. 
0 in. 
3 in. 
Bottom 
0 in. 
0 in. 
1 in. 
1 in. 
1 in. 
S/A 
Plenum
 
0 in. 
1 in. 
1 in. 
1 in. 
3 in. 
Rear 1 
in.
1
 
1 in. 
1 in. 
1 in. 
1 in 
Sides 6 
in.
2
 
1 in. 
1 in. 
1 in. 
0 in. 
Front 
24 in. 
6 in.
1
 
24 in. 
16 in.
1
 24 
in. 
Flue Pipe 
9 in.
3
 9 
in.
3
 9 
in.
3
 9 
in.
3
 9 
in.
3
 
Enclosure 
Standard 
Closet 
- - - 
Closet 
Alcove 
 
1
 24 inches is required for servicing. 
 
2
 18 inches is required on one side as service access to rear. 
 
3
 18 inches required in some U.S. jurisdictions 
 
Fig. 1: 
Typical Suspended Application