Vogelzang International Stove TR008 Benutzerhandbuch

Seite von 22
Page  
DURANGO™
 
TR008 / 050207.3
Locating Stove
Fig. 3 – Top View  Minimum Clearance Dimensions from Combustible Surfaces
FLOOR
PROTECTOR
DASHED LINES SHOW HORIZONTAL CHIMNEY CONNECTOR
AND ADDITIONAL FLOOR PROTECTOR REQUIRED BENEATH
                                  AND EXTENDING 2” BEYOND EACH SIDE
NON COMBUSTIBLE CONSTRUCTION IN ACCORDANCE WITH NFPA 211
BACKWALL
SIDEWALL
30"
4 8"
18"min.
6"min.
17"
22"
min.
11"min.
TOP VIEW
  29"
1.  The  stove  must  be  placed  on  solid  concrete, 
solid  masonry,  or  when  installed  on  a  com-
bustible floor, on a listed floor protector, such 
as  Hy-C  or  Imperial  Model  UL  3648BK  or 
equivalent with 0.8 R-factor. (NOTE: to calcu-
late R-value of alternative materials see page 
20). The floor protector must extend at least 
18” beyond the front of the access door, 6” to 
the sides, and must extend under and 2 inches 
Continued on next page
beyond  either  side  of  the  stove  pipe  if  it  is  
elbowed towards a wall. (See figures 3 & 5 and 
consult  local  building  codes  and  fire  protec-
tion ordinances). A grouted ceramic floor tile 
installed per local building code is considered 
a durable equivalent.
CAUTION:  (FIre  HAzArd)  CArpeTINg  ANd 
OTHer  COmbUsTIble  mATerIAl  sHAll 
NOT COver THe FlOOr prOTeCTOr. THese  
mATerIAls  mUsT  remAIN  OUTsIde  OF   
COmbUsTIble CleArANCes, see FIg. 3 – 5.
2.  The stove must have its own flue. Do not  
connect  this  unit  to a  chimney 
flue serving other appliances.
3.  After  observing  the  clearances  to  combus-
tible materials (figures 3–5), locate your floor  
protector  accordingly  (figure  1)  and  care-
fully place the stove in your selected location.   
Install  stove  pipe,  elbows,  and  thimble  as  
required,  utilizing  either  a  recently  cleaned 
and inspected 6”  masonry chimney or a 6” i.d. 
listed type HT chimney.
4.  Use  6”  round  black  stove  pipe,  not  
galvanized stove pipe. Secure each pipe section 
with three (3) sheet metal screws in each stove 
pipe and/or elbow joint to firmly hold the pipe 
sections together. Do not connect this 
stove to any air Distribution or 
Duct system.
10. Attach blower assembly to rear of the back heat 
shield with four Phillips head machine screws 
from the hardware pack. Make sure to position 
the ceramic gasket between the back heat shield 
and the blower assembly. 
11. After properly locating floor protector (fig 3) 
to  accommodate  minimum  stove  clearances, 
place stove in position on floor protector.
12. Route the power cord away from stove. Do not 
allow the power cord to touch any hot surfaces. 
Keep power cord at least 12” from stove sur-
faces.
13. Check to make sure that the bottom fire bricks 
(#13) and ceramic fiber boards (parts #18 & 
#19) above the air tube assembly (#6) have not  
shifted during shipping or assembly.
14. Once stove is positioned, plug power cord into 
a grounded 120v outlet.
aSSembLy inStructionS  continued…