Vogelzang International Stove TR008 Benutzerhandbuch

Seite von 22
Page  
DURANGO™
 
TR008 / 050207.2
lOCATINg STOvE 
1.  The tapered end of the connector stovepipe fits 
into the stove flue collar. 
2.  Horizontal  pipe  runs  must  slope  upwards  
towards the chimney at least 1/4” per foot of 
horizontal run.
3.  You must have at least 18 inches of clearance 
between  any  horizontal  piping  and  the  ceil-
ing.
4.  The pipe cannot extend into the chimney flue 
(figure 7).
5.  Secure pipe/elbow sections with three (3) sheet 
metal screws at each joint to make the piping 
rigid.
6.  It is recommended that no more than two (2) 90 
degree bends be used in the stovepipe installa-
tion. The use of more than two 90 degree bends 
may decrease the amount of draw and possibly 
cause smoke spillage. Where possible, use only 
corrugated (nonadjustable) elbows. These pro-
vide a better seal.
7.  The connector pipe must not pass through an 
attic  or  roof  space,  closet,  or  any  concealed 
space,  or  floor,  ceiling,  wall  or  combustible 
construction.  (See  Chimney  Connector  Sys-
tems & Clearances, page 19). A UL 103 HT 
Listed  chimney  must  be  used  from  the  first 
penetration of ceiling or wall to the chimney 
cap. Never use single wall connector pipe as 
a chimney - a house fire could result. 
Fig.7 – Stovepipe/Flue Connections
 
 
CORRECT 
wRONG 
wRONG
NOTE: CONNECTOR PIPE IS NOT INClUDED
TO  PURCHASE, VISIT YOUR  LOCAL  HARD-
wARE,  HOmE  OR  BUILDING  CENTER.  SEE   
“LOCATING STOVE” PAGE 4  FOR ADDITIONAL 
SPECIFICATIONS.
CONNECTOR PIPE INSTAllATION
Fig.6 Firebrick
 Installation
CAUTION:  REPLACE  FIREBRICkS  BEFORE 
FIRING wOODSTOVE. POSITION FIREBRICkS 
SO NO GAPS REmAIN  BETwEEN BRICkS.
FIREBRICk ASSEmBLY
 
Firebrick protects the stove body, extends the 
life of your stove and radiates heat more evenly. 
Check to see that all firebricks are in their correct 
positions  and  have  not  become  misaligned  dur-
ing shipping or assembly. If removed for ease of  
locating stove, firebrick must be replaced before 
firing.  There  are  four  different  full-sized  bricks  
(A,  K,  F,  D)  and  three  (E,  G,  H)  with  notches.  
See diagram, fig. 6, for proper positioning. 
CAUTION:  NEVER  OPERATE  STOVE wITH 
mISSING OR CRACkED FIRE BRICkS!