D-6 DRAFT DAmpER 
A Draft Damper included with the stove must be 
installed in the first straight section of pipe exit-
ing the stove before the stove pipe is connected 
and the cook stove is used. 
1.  Drill two 1/4” holes centered on either side of 
the pipe section 6” from the top end of the pipe 
(figure 6).
2.  Remove the handle from the damper then slide 
the damper into the pipe.
3.  Align the damper with the holes drilled in step 
1 and insert the handle through the holes and 
the damper.
NoTe: This damper is necessary for the proper 
operation  of  the  stove  and  to  meet  EPA  
emissions  requirements  for  heating  appli-
ances.  It  MUST  be  installed  before  use
(No eXcePTIoNS) 
Proper  clearances  must  be  maintained  for  ad-
equate  air  circulation. Adequate  ventilation  must  be  
provided while operating this stove.
1.  The  stove  must  be  placed  on  solid  con-
crete,  solid  masonry,  or  when  installed  on  a  
combustible  floor,  on  a  Underwriters  Labora-
tory  Listed  floor  protector,  such  as  Hy-C  or 
Imperial  Model  UL  5659.  The  base  must  ex-
tend at least 18” beyond the front of the hearth, 
18”  to  the  sides  of  the  stove,  and  must  extend  
under the stove pipe if it is elbowed towards a wall 
(see figure 2 and consult local building codes and 
fire protection ordinances.)
Fig. 2 –   Minimum Clearance Dimensions from Combustible Surfaces
COMBUSTIBLE
CONSTRUCTION 
ACCORDING TO 
NFPA 211
FLOOR
PROTECTOR
DASHED LINE SHOWS
HORIZONTAL CHIMNEY
CONNECTOR AND
ADDITIONAL FLOOR
PROTECTION REQUIRED
BACKWALL
56"
(TOP VIEW)
18"
18"
36"
36"
59"
18"
SIDEWALL
COMBUSTIBLE
CONSTRUCTION 
ACCORDING TO
NFPA 211
2.  The stove must have its own flue. 
DO NOT CON-
NECT THIS  UNIT TO  A  CHImNEY  FLUE 
SERVING OTHER APPLIANCES.
3.  After  observing  the  clearances  to  combus-
tible  materials  (figure  2  &  3),  locate  your  floor  
protector  accordingly  (figure  2)  and  careful-
ly  place  the  stove  in  your  selected  location.   
Install  stove  pipe,  elbows,  and  thimble  as  
required,  utilizing  either  a  recently  cleaned  and 
inspected 6” masonry chimney or a 6” i.d. listed 
chimney. Maximum 64 square inches.
Continued on page 4
6"/15.25 cm
Draft Damper
(must be installed 
before use — NO 
EXCEpTIONS!)
lOCATINg STOvE
Fig. 1
Draft Damper
Installation